Skip to main content

Table 1 Sealant test results.

From: Investigation of Likelihood of Cracking in Reinforced Concrete Bridge Decks

Test site #

Product

Components

Viscosity (cps)

Elongation (%)

Curing time (h)

Skid ave.

Tensile strength ave. (kN)

TS-1

1

2 part epoxy

30

5.5

2–3

62

7.08

TS-2

2

3 part methacrylate

5–20

40–50

4–6

37

10.51

TS-3

3

2 comp methacrylate

5–15

5.5

1

22

5.68

NAa

4

2 comp methacrylate

1,100–1,500

220–300

 

–

–

TS-5

5

3 part methacrylate

14–15

20

4–6

37

7.70

NAa

6

3 part methacrylate

14–15

30

6

–

–

TS-6

7

Epoxy

80

60

2

50/74

9.95/9.96

TS-4

Control

No sealer applied

   

48

10.19

  1. aNot applied.