Table 3 Results of testing the sealant materials in the laboratory.

From: Investigation of Likelihood of Cracking in Reinforced Concrete Bridge Decks

Manufacturer’s data

Lab test data (first attempt)

Lab test data (second attempt)

Product

Tensile strength

Viscosity (cps)

Elongation (%)

Tensile strength

Elongation (%)

Tensile strength

Elongation (%)

MPa

MPa

MPa

1-A

56.4

5–15

5.5

22.6

2.1

25.3

2.6

2-B

41.0–47.9

30

3–7

23.4

10.5

27.2

N/A

3-C

19.3

5–20

40–50

0.9

99.6

7.3

17.2

4-D

8.2

10–25

30

No test

No test

5.7

1.3

5-E

6.9

80

60

3.3

213

5.4

102