Skip to main content

Table 4 Statistical results of dynamic modulus values obtained resonance of 10 cm core samples, with regard to aggregate type and temperature condition.

From: Effect of Mixing and Placing in Hot Weather on Hardened Concrete Properties

Groups

Count

Mean (GPa)

Variance (GPa)

All, limestone

7

31.1

2.70

All, river rock

6

38.4

7.40

All, hot

7

33.0

16.3

All, cold

6

36.2

18.6