Skip to main content

Table 4 Comparison of prism test and calculation result.

From: Compression Behavior of Form Block Walls Corresponding to the Strength of Block and Grout Concrete

Specimen name

Test result

Mortar factor e s

Fm,c1 (MPa)

Fm,c2 (MPa)

F m , exp F m , c 1

F m , exp F m , c 2

Ultimate load (kN)

Ultimate strength Fm,exp (MPa)

B1-C1

514.96

13.20

0.79

20.88

11.49

0.63

1.15

B2-C1

571.06

14.64

0.47

26.55

14.60

0.55

1.00

B3-C1

627.04

16.08

0.46

26.79

14.73

0.60

1.09

B4-C1

692.66

17.76

0.43

27.81

15.30

0.64

1.16

B1-C2

824.58

21.14-

0.79

31.74

17.46

0.67

1.21

B2-C2

1025.5

26.29

0.47

37.40

20.57

0.70

1.28

B3-C2

1110.32

28.47

0.46

37.64

20.70

0.76

1.38

B4-C3

1105.1

28.34

0.43

38.67

21.27

0.73

1.33

Avg.

     

0.66

1.20