Skip to main content

Table 8 Effect of steel fiber dosage and beam size on flexural capacity of UHPC.

From: Ultra-High Performance Concrete: Mechanical Performance, Durability, Sustainability and Implementation Challenges

References

Fiber (L/D) (mm/mm)

Fiber content (%)

Specimen size (mm)

Flexural strength (MPa)

Collepardi et al. (1997)

13/0.18

2.5

150 × 150 × 600

20.2

40 × 40 × 160

48.3

Herold and Muller (2004)

8/0.17

0.0

40 × 40 × 160

21.1

0.5

25.3

2.5

34.1

4.0

46.2

Bornemann and Faber (2004)

9/0.15

2.0

150 × 150 × 700

22.0

Guvensoy et al. (2004)

6/0.15

5.0

70 × 70 × 280

30.3

5.5

49.2

6.0

54.4

Orgass and Klug (2004)

13/0.16

0.0

150 × 150 × 700

10.6

1.0

11.9

2.0

13.4

0.0

100 × 100 × 500

9.8

1.0

11.2

2.0

14.7

0.0

40 × 40 × 160

9.9

1.0

11.6

2.0

18.3

Soutsos et al. (2005)

12/0.16

0.0

40 × 40 × 160

18.4

1.5

37.3

2.0

40.3

Allena and Newtson (2010)

13/–

0.0

75 × 100 × 400

10.9

1.5

18.3

Wille and Parra-Montesinos (2012)

13/0.20

1.5

152 × 152 × 508

14.8

102 × 102 × 406

15.8

Magureanu et al. (2012)

25/0.40 + 6/0.17

0.0

40 × 40 × 160

13.9

2.5

34.0

0.0

100 × 100 × 300

9.4

2.5

23.0

Kazemi and Lubell (2012)

13/0.2

0.0

50 × 50 × 150

22.1

2.0

29.1

4.0

48.0

0.0

100 × 100 × 300

15.0

2.0

23.1

4.0

38.4

Kreiger et al. (2012)

14/0.18

2.0

51 × 51 × 229

18.4

51 × 51 × 343

19.8

51 × 51 × 457

17.5

51 × 51 × 699

18.0

76 × 76 × 343

19.0

Shu-hua et al. (2012)

18/0.20

0.0

40 × 40 × 160

26.9

1.0

27.6

2.0

29.2

0.0

100 × 100 × 400

17.7

1.0

18.9

2.0

20.0

Nguyen et al. (2013)

(30/0.3 twisted) + (13/0.2 smooth)

1.0 + 0.5

50 × 50 × 150

29.6

1.0 + 1.0

38.9

1.0 + 0.5

100 × 100 × 300

23.9

1.0 + 1.0

29.1

1.0 + 0.5

150 × 150 × 450

20.5

1.0 + 1.0

26.9