Skip to main content

Table 6 Compressive strength test results.

From: Mechanical Properties of Energy Efficient Concretes Made with Binary, Ternary, and Quaternary Cementitious Blends of Fly Ash, Blast Furnace Slag, and Silica Fume

Specimen name

Water-binder (W/B) ratio (%)

Compressive strength (Unit: MPa)

Ratio of compressive strength at 7 days to strength at 28, 56 and 91 days

7 days

28 days

56 days

91 days

7/28

7/56

7/91

Group I

FA15

40

35.2

44.6

52.2

55.6

0.79

0.67

0.63

FA25

31.1

41.2

45.3

48.8

0.75

0.69

0.64

SF5

53.0

63.9

71.5

71.9

0.83

0.74

0.74

BS25 + FA25

23.0

42.9

53.9

60.2

0.54

0.43

0.38

BS30 + FA30

15.8

36.3

41.7

51.0

0.44

0.38

0.31

BS50

25.8

48.9

57.5

67.1

0.53

0.45

0.38

BS65 + SF5

19.4

40.4

50.2

56.4

0.48

0.39

0.34

Group II

FA25

34

41.0

50.4

53.3

63.6

0.81

0.77

0.64

SF5

64.5

72.8

84.6

86.1

0.89

0.76

0.75

BS25 + FA25

29.5

53.5

65.3

70.4

0.55

0.45

0.42

BS30 + FA30

21.1

45.8

56.3

60.9

0.46

0.37

0.35

BS50

29.8

53.4

65.7

69.3

0.56

0.45

0.43

BS65 + SF5

26.2

55.7

68.4

69.3

0.47

0.38

0.38

Group III

FA25 + SF5

28

53.6

73.2

77.7

80.6

0.73

0.69

0.67

SF5

73.6

83.6

90.9

93.2

0.88

0.81

0.81

BS25 + FA20 + SF5

43.2

73.7

83.9

88.3

0.59

0.51

0.49

BS30 + FA25 + SF5

29.6

57.4

63.7

73.0

0.52

0.46

0.41

BS45 + SF5

46.3

76.5

85.0

89.4

0.61

0.54

0.52

BS65 + SF5

37.4

72.5

80.6

81.6

0.52

0.46

0.46