Skip to main content

Table 14 Flow diameter, density, compressive strength, compressive strain and electrical resistivity values of various cement mixes.

From: Assessment of Rheological and Piezoresistive Properties of Graphene based Cement Composites

Sample

Flow diameter (mm)/percentage rate (%)

Density (kg m−3) percentage rate (%)

Maximum compressive load (kN)/percentage rate (%)

Compressive strength (MPa)/percentage rate (%)

Compressive strain at maximum compressive load (mm/mm)/percentage rate (%)

Four probe resistivity at maximum compressive loading (kΩ-cm)/percentage rate (%)

Mo

225/100

2155.6/100

93.6/100

58.5/100

0.0086/100

69.8/100

GM3

213/94.6

2045/94.9

103.6/110.6

64.7/110.6

0.012/147.2

22.5/32.2

GM5

211/93.8

2150.7/99.8

109.2/116.7

68.3/116.7

0.014/170.1

28.3/40.5

GM10

204/90.7

2077.4/96.4

95.4/101.9

59.6/101.9

0.013/153.6

35.4/50.8