Skip to main content

Table 5 Key mechanical parameters used in the model verification.

From: Experimental Investigation on Damage Behavior of Polypropylene Fiber Reinforced Concrete under Compression

No.

Literatures

Specimen

Dimension (mm)

V (%)

l/d

fc (MPa)

εcu (10−3)

Monotonic loading

 (a)

Alhozaimy et al. (1996)

Cylinder

\(\Phi\)152 × 305

0.2

400

42.35

2.05

 (b)

Chi et al. (2014)

Prism

150 × 150 × 300

0.1

167

28.35

1.96

 (c)

Libre et al. (2011)

Cylinder

\(\Phi\)150 × 300

0.4

750

16.52

3.64

 (d)

Aslani and Nejadi (2013)

Cylinder

\(\Phi\)150 × 300

0.55

76.5

37.22

1.92

 (e)

Current study

Prism

150 × 150 × 300

0.15

280

32.43

1.78

 (f)

Karsan and Jirsa (1969)

Cylinder

\(\Phi\)150 × 300

27.51

2.02

Cyclic loading

 (a)

Karsan and Jirsa (1969)

Cylinder

\(\Phi\)150 × 300

24.62

1.75

 (b)

Current study

Prism

150 × 150 × 300

0.15

280

32.41

1.78