Table 2 Description of selected residential building and field test.

From: Feasibility of a Radiant Floor Cooling System for Residential Buildings with Massive Concrete Slab in a Hot and Humid Climate

Parameter

Description

House

 Location

Seoul, South Korea

 Orientation

Rooms 1 and 2: South

Room 3 and living room: North

 Area

76.5 m2

 Occupancy

Total of 16 persons (M: 8, W: 8)

4 persons/day

Ages 25–35

 Air-tightness

7.4 ACH at ΔP=10 Pa

Radiant floor cooling system

 Heat source

Chiller (2 USRT)

 Radiant floor panel

Supply water temperature 16 °C

Pipe diameter 16 mm

Pipe space 230 mm

 Control

Individual room control (on/off)

Supplementary equipment

 Fan coil unit

4 way type

Supply water temperature 7–10 °C

 Control

On/off control

Measurement

 Room temperature

T-type thermocouple

Center of room (height 1.2 m)

 Relative humidity

Center of room (height 1.2 m)

 Floor surface temperature

5 locations for each room

 Equipment

NI SCXI with LabVIEW 8.0

Adjustable variables

Set room temperature

Set minimum floor surface temperature

Field test period

1 month (August)