Skip to main content

Table 3 Concrete chloride experimental type.

From: Prediction of Chloride Penetration Depth Rate and Diffusion Coefficient Rate of Concrete from Curing Condition Variations due to Climate Change Effect

Code

Name

Volt

ASTM C 1202

Standard test method for electrical indication of concrete ability to resist chloride ion penetration

60 V

NT Build 492

Chloride migration coefficient from non–steady state migration experiments

10–60 V

NT Build 355

Chloride diffusion coefficient from migration cell experiments

12 V

NT Build 443

Accelerated chloride penetration

–