Skip to main content

Table 5 Detailed information of each specimen.

From: Experimental Quantification on the Residual Seismic Capacity of Damaged RC Column Members

Specimen

Failure mode

L (mm)

Cross section (mm2)

Concrete cover (mm)

fc (MPa)

fy (MPa)

fyt (MPa)

S (mm)

ρsh (%)

Axial force

FF-15S

Flexural failure

1800

400 × 400

40

21 (37.0a)

420

280

150

0.61

0.1Agfc’

Flexural failure

1800

400 × 400

40

21 (33.1a)

420

280

150

0.61

0.2Agfc’

FSF-15S

Flexural–shear failure

1800

400 × 400

40

21 (34.6a)

420

280

150

0.31

0.1Agfc’

Flexural–shear failure

1800

400 × 400

40

21 (30.8a)

420

280

150

0.31

0.2Agfc’

SF-30S

Shear failure

1800

400 × 400

40

21 (34.1a)

420

280

300

0.15

0.1Agfc’

Shear failure

1800

400 × 400

40

21 (33.2a)

420

280

300

0.15

0.2Agfc’

  1. aThe measured compressive strength of concrete at the testing time.