Table 6 Partial test results.

From: Experimental Studies on Bond Performance of BFRP Bars Reinforced Coral Aggregate Concrete

Test piece number

Nominal diameter/mm

Bond length/mm

Design strength of coral concrete/MPa

Fmax/kN

Smax/mm

τmax/MPa

Failure modes

B6-5d-C30

6

5d

C30

8.60

1.88

15.21

P

B8-5d-C30

8

5d

C30

15.10

1.66

15.03

P

B10-5d-C30

10

5d

C30

22.73

1.46

14.48

P

B10-10d-C30

10

10d

C30

41.25

1.40

13.14

P

B10-12d-C30

10

12d

C30

47.75

0.78

12.67

F

B12-5d-C30

12

5d

C30

32.10

2.84

14.20

P

B16-5d-C30

16

5d

C30

53.95

1.63

13.42

S

B20-5d-C30

20

5d

C30

66.05

2.39

10.52

S

B10-10d-C20

10

10d

C20

31.80

1.73

10.13

P

B10-10d-C15

10

10d

C15

26.25

1.46

8.36

P

  1. The meaning of each symbol in the table: “d” denotes the diameter of BFRP rebar, “Fmax” denotes the ultimate bonding force; “Smax” denotes the amount of slip of the BFRP rebar when the maximum pulling force is reached; “τmax”denotes Average bond stress at maximum pull force; Destructional forms: “P” denotes pull-out failure, “F” denotes fracture failure, “S” denotes splitting failure. The data listed in the table are represented by the results of the three specimens in each group with its closest to the average value of their maximum drawing force.