Skip to main content

Table 12 Measured and predicted force at residual shear crack width of 0.30 mm.

From: Experimental Investigation on the Force-Crack Quantification Model for HSRC Columns with Flexure–Shear and Shear Failure Modes

Specimen

Measured force (kN)

Predicted force (kN)

Measured force/predicted force

10S0.15

2222

1822

1.22

10S0.30

2551

2081

1.23

15S0.15

1929

2087

0.92

15S0.30

2023

2179

0.93

20S0.15

1761

1679

1.05

20S0.30

2160

1859

1.16