Table 13 Measured and predicted force at residual shear crack width of 1.00 mm.

From: Experimental Investigation on the Force-Crack Quantification Model for HSRC Columns with Flexure–Shear and Shear Failure Modes

Specimen

Measured force (kN)

Predicted force (kN)

Measured force/predicted force

10S0.15

2282

2485

0.92

10S0.30

2563

2268

1.13

15S0.15

2200

1643

1.34

15S0.30

2432

1922

1.27

20S0.15

1835

1429

1.28

20S0.30

2231

1690