Skip to main content

Table 4 Cyclic loading test results of the specimens.

From: Experimental Study on the Cyclic Performance of Reinforced Concrete Shear Walls Exposed to Fire

Specimen

Fmax+

(kN)

Fmax-

(kN)

Fmax, avg

(kN)

Drift at Fmax (%)

LFC

267.9

−263.1

265.5

 + 1.25/− 1.25

LFH1

254.6

−247.6

251.2

 + 1.25/− 2.00

LFH2

240.6

−241.38

241.0

 + 1.60/− 2.00

LSC

576.6

−579.4

578.0

 + 2.00/− 2.00

LSH1

552.2

−540.5

546.3

 + 2.00/− 2.50

LSH2

522.4

−577.9

550.2

 + 2.50/− 2.50

QFC

632.61

−591.3

611.9

 + 0.75/1.00

QFH2

560.6

−571.7

566.2

 + 1.25/− 1.25

QSC

946.9

−964.6

955.8

 + 1.00/− 1.00

QSH2

945.9

−929.3

937.6

 + 1.60/− 1.60

  1. Fmax+  = the maximum lateral loads of positive directions; Fmax- = the maximum lateral loads of negative directions; Fmax, avg = averaged value of Fmax+ and Fmax-