Skip to main content

Table 1 Electrical resistance values and their corresponding standard deviations obtained from the I–V curves characterization.

From: Toward Structural Health Monitoring of Civil Structures Based on Self-Sensing Concrete Nanocomposites: A Validation in a Reinforced-Concrete Beam

CNTs (\(\% wt\)) Average electrical resistance (\(\Omega\)) Standard deviation (\(\Omega\))
0.2 5335505.50 250871.25
0.5 88245.70 3813.08
0.8 693.32 14.99