From: Toward Structural Health Monitoring of Civil Structures Based on Self-Sensing Concrete Nanocomposites: A Validation in a Reinforced-Concrete Beam
CNTs (\(\% wt\))
Average electrical resistance (\(\Omega\))
Standard deviation (\(\Omega\))
0.2
5335505.50
250871.25
0.5
88245.70
3813.08
0.8
693.32
14.99