Vs, TR(kN) | Vfib (kN) | Vs, fib/Vfib, exp (%) | Remarks | |
---|---|---|---|---|
Type 0 | ||||
Vfib, exp | – | 185.1 | 100 | Fiber effect is: • calculated by experimental value |
Vs, 0.16 | 163.4 | – | 88.3 | |
Vs, 0.21 | 267.7 | – | 144.6 | |
Vs, 0.32 | 311.8 | – | 168.4 | |
Type 1 | ||||
Vfib, AT | – | 71.7 | 38.7 | Fiber effect is: • separate from concrete contribution • accounted for by using fiber factor |
Vfib, SRN | – | 97.2 | 52.5 | |
Vfib, KM | – | 135.0 | 72.9 | |
Vfib, HA | – | 205.3 | 110.9 | |
Vfib, YHE | – | 154.5 | 83.5 | |
Type 2 | ||||
Vfib, SAK | – | 93.2 | 50.4 | Fiber effect is: • included in concrete contribution • accounted for by using SFRC material properties in tension |
Vfib, FSJ | – | 83.9 | 45.3 | |
Vfib, RIL | – | 53.1 | 28.7 | |
Vfib, AC | – | 81.4 | 44.0 | |
Vfib,SN | – | 58.9 | 31.8 |