Table 3 Draw-in slips at anchorages in full-scale specimen.

From: Analysis of Short-Term Prestress Losses in Post-tensioned Structures Using Smart Strands

Duct Smart Strand Slip (mm)a
T1 H1 5.1
H7 5.3
H12 4.4
T2 H7 5.9
H11 5.1
H12 5.0
T3 H1 6.4
H7 6.6
H12 6.4
  1. aAverage: 5.6 mm, coefficient of variation: 13.0%.