Skip to main content

Table 3 Thermal conductivity (κ), thermal resistance (R), overall heat transfer coefficient (U), temperature difference (ΔT) and heat transfer rate (Q) of GMT_0, GMT_0.01, GMT_0.03, GMT_0.05, and GMT_0.1 composites.

From: The Mechanical and Thermal Properties of Cement CAST Mortar/Graphene Oxide Composites Materials

Samples

Thermal conductivity (W/mK)

Thermal resistance (m2K/W)

Overall heat transfer coefficient (W/m2K)

Temperature difference (oC)

Heat transfer rate (W/min)

20 min

30 min

20 min

30 min

GMT_0

0.577 ± 0.007

0.087

11.556

276.20

270.58

0.793

0.523

GMT_0.01

0.568 ± 0.022

0.088

11.369

278.00

269.94

0.783

0.514

GMT_0.03

0.548 ± 0.025

0.091

10.972

278.92

271.84

0.757

0.498

GMT_0.05

0.512 ± 0.027

0.098

10.252

277.52

271.40

0.705

0.465

GMT_0.1

0.489 ± 0.025

0.102

9.792

277.48

270.78

0.674

0.443