Skip to main content

Table 3 Mix ratio of hybrid-fiber-reinforced concrete.

From: Mechanical Characteristics of Hybrid-Fiber-Reinforced Concrete Shaft Wall Structure Under Uneven Load

Strength grade

Water-to-binder ratio

Cement/ kg m−3

Admixture/kg m−3

Basalt gravel/ kg m−3

Percentage of sand/%

PVA content/ %

PPTF content/ %

HFRC 60

0.28

410

130

1121.5

36

0.084

0.549

HFRC 70

0.27

420

140

1111.0

36

0.084

0.549

HFRC 80

0.26

430

155

1096.3

36

0.084

0.549