Skip to main content

An Experimental Study on Shear Strength of Chemically-Based Self-Consolidating Concrete

Abstract

An experimental investigation was conducted to compare the shear strength of full-scale beams constructed with chemically-based, self-consolidating concrete (SCC) with conventional concrete (CC). This experimental program consisted of 16 rectangular beams (12 without shear reinforcing and 4 with shear reinforcing in the form of stirrups), 8 beams for each mix design. Additionally, three different longitudinal reinforcement ratios were evaluated within the test matrix. The beam specimens were tested under a simply supported four-point condition. The experimental shear strengths of the beams were compared with both the shear provisions of selected standards (U.S., Australia, Canada, Europe, and Japan) and a shear database of CC specimens. This comparison indicates that chemically-based SCC beams possess comparable shear strength as CC beams.

1 Introduction

Self-consolidating concrete (SCC) is a highly workable concrete that can spread under its own weight without segregation and bleeding. SCC was developed in Japan in the early 1980s by Okamura and colleagues at Tokyo University (Ozawa et al. 1989). The motivation for this development was a lack of skilled workers for compacting concrete to make durable concrete structures (Daczko and Vachon 2006).

Like many new products, SCC was slow to gain popularity. It was used for the first time on a large scale for the Akashi-Kaikyo bridge in Japan in 1998 (Okamura 1997). It began to spread in Asian and European countries before the United States. It gained acceptance in the United States around the year 2000 (Daczko and Vachon 2006).

SCC has become more popular because of several advantages. It reduces labor, equipment, job noise, and time of construction. It also facilitates the filling of densely reinforced sections and complex formworks (ACI 237R- 07).

Comprehensive research has been done on both fresh and hardened properties of SCC, but relatively little research have been performed on the structural behavior of SCC. With regard to shear behavior, results from multiple researchers have shown somewhat conflicting results. Das et al. (2005) found that SCC beams had higher shear strength compared to conventional concrete (CC). Wilson and Kiousis (2005) reported, however, that shear provisions within the American Concrete Institute (ACI 318) did not always yield conservative results for SCC beams. Test results from Burgueño and Till (2005), Bendert and Burgueño (2006a, b) showed that the shear behavior of both SCC and CC beams are very similar to each other. In addition, the ultimate shear strength of SCC and CC beams were almost the same. Hassan et al. (2008, 2010) and also Choulli and Mari (2005) reported there was no significant difference between the shear behavior of SCC and CC beams, and that the ultimate shear strength of SCC beams was only slightly lower than CC beams. Dymond et al. (2007, 2009, 2010) tested a single, precast bulb-tee bridge girder and concluded that the theoretical prediction of the simplified method was conservative compared with experimental test results of the beam. These conflicting results may be attributed to the specific SCC mix designs for each study; limited information was provided on each researcher’s SCC mix design. With aggregate interlock playing such a critical role in shear behavior (Taylor 1970, 1972, 1974), SCC mixes that rely on material-based changes—higher paste contents and smaller rounded aggregates—may result in substantially reduced shear strength.

There are three different approaches to developing an SCC mix design. The first is material-based, the second is chemically-based, and the third is a hybrid of the first two. The first approach focuses on modifying the aggregate types and amounts. Typically, the coarse aggregate content is reduced and also rounder aggregate is used to improve the flowability of the SCC mix. The main disadvantage of this approach is that with a lower coarse aggregate content, aggregate interlock, and as a result shear strength, is reduced. To avoid this issue, the second approach was developed and, in this approach, the coarse aggregate and paste contents are kept the same as in a CC mix. To improve the flowability and stability of this type of mix, high-range water-reducing admixtures (HRWRA) and viscosity-modifying admixtures (VMA) are used.

All of the aforementioned previous research studied shear behavior of SCC that used the first or third approaches for mix design. This study presents the results of an experimental investigation that compares the shear strength of full-scale SCC beams—constructed with a chemically-based mix—with shear provisions of the selected codes and a shear database of CC specimens.

2 Experimental Program

2.1 Specimen Design

Eight beams (six without shear reinforcing and two with shear reinforcing in the form of stirrups) with three different longitudinal reinforcement ratios for each concrete type were designed to preclude flexural failure and satisfy the minimum and maximum longitudinal reinforcement requirements of ACI 318-11. All beams tested in this program had a rectangular cross section with a width of 300 mm and a height of 460 mm and shear span-to-depth ratios of 3.0 or greater (see Table 1; Fig. 1). The beam designation included a combination of letters and numbers: NS and S stand for no stirrups and stirrups, respectively. The numbers 4, 6, and 8 indicate the number of #22 longitudinal reinforcement bars within the tension area of the beam section. For example, NS-6 indicates a beam with no stirrups and 6 #22 bars within the bottom of the beam (Table 1).

Table 1 Shear beams test matrix.
Fig. 1
figure 1

Cross sections and reinforcement layout of the beams.

2.2 Materials and Mixture Proportions

Materials used for this study include: Type I Portland cement, ASTM specified Class C fly ash from the Ameren Labadie Power Plant (Labadie, MO), crushed limestone with a maximum nominal aggregate size of 19 mm from Jefferson City Dolomite (Jefferson City, MO), and sand from Missouri River Sand (Jefferson City, MO). The HRWRA, VMA, and air-entraining admixture used for this research were Glenium 7500, Rheomac 362, and MB-AE-90, respectively. The longitudinal steel consisted of ASTM A615, Grade 60, 414 MPa material while the shear reinforcement was ASTM A615, Grade 40, 276 MPa.

The intent of this research project was to determine whether a chemically-based SCC mix would experience a decrease in shear strength compared to CC. Consequently, the SCC mix design followed conventional proportioning in terms of aggregate type and content, cement content, air content, water-cementitious material ratio, and workability. Then, using only chemical admixtures, the authors converted this CC mix to an SCC mix with all of the necessary passing, filling, flowability, and stability requirements typically found in SCC. The high fluidity was achieved with a polycarboxylate-based HRWRA, while the enhanced stability was accomplished with an organic, polymer-based VMA. The concrete mixture proportions and fresh concrete properties are given in Tables 2 and 3, respectively. A local ready-mix concrete supplier (Rolla, MO) delivered the concrete mixture, which had a target compressive strength of 35 MPa.

Table 2 Mixture proportions of concrete.
Table 3 Fresh mixture properties.

2.3 Fabrication and Curing of Test Specimens

Specimens were constructed and tested in the Structural Engineering High-Bay Research Laboratory (SERL) at Missouri University of Science and Technology. After casting, both the beam specimens and the quality control/quality assurance companion cylinders (ASTM C39-12 and C496-11) and beams (ASTM C78-10) were covered with both wet burlap and a plastic sheet. All of the full-scale beams and companion cylinders and beams were moist cured for 3 days and, after formwork removal, were stored in the laboratory until they were tested.

2.4 Test Setup and Procedure

A load frame was assembled and equipped with two 490-kN, servo-hydraulic actuators intended to apply the two point loads to the beams, as shown in Fig. 2. The two actuators were operated in a displacement control mode, with one actuator slaved to the other in order to apply load symmetrically to the frame, and thus the beam. The loading rate was set at 0.50 mm/min and controlled through the mechanism of the actuator (i.e., displacement of the actuator head and thus load point on the beam). The shear beams were supported on a roller and a pin support, 300 mm from each end of the beam, creating a four-point loading situation with the two actuators. Linear variable differential transformers (LVDT’s) and strain gauges were used to measure the deflection at the beam center and strain in the reinforcement. The strain gauges were installed on the lower layer of the bottom longitudinal reinforcement at midspan (maximum flexural moment location) and quarter point along the span (middle of the shear test region). For the sections with stirrups, 10 additional strain gauges were installed on the stirrups. Figure 2 shows both the beam loading pattern and the location of the strain gauges. The diagonal pattern of the stirrup strain gauges followed the anticipated critical shear crack based on previous testing of similar specimens. During the test, any cracks that formed on the surface of the beam were marked at 22 kN load increments, and both the deformation and strains were monitored until the beam reached failure.

Fig. 2
figure 2

Load pattern and location of strain gauges on the test beams.

3 Test Results

Table 4 summarizes the compressive strength at time of testing, shear force, V test , average shear stress at failure, V test /b w d, ratio of the average shear stress to compressive stress, v test /f c ′, and ratio of the average shear stress to square root of the compressive strength, v test /√f c ′, to compare with ACI 318-08 shear provisions, Eqs. 13, rewritten as Eq. (1).

V c = 0.17 λ f c b w d
(1)

where V c is the nominal shear strength provided by concrete (N), λ is the modification factor reflecting the reduced mechanical properties of lightweight concrete, f c ′ is the specified compressive strength of concrete (MPa), d is the distance from extreme compression fiber to centroid of longitudinal tension reinforcement (mm), b w is the web width (mm).

Table 4 Test results summary.

As can be seen from Table 4, The average shear stress of the CC beams varies from 2.6 to 4.9 % of the compressive strength, while the average shear stress of the SCC beams varies from 2.0 to 4.1 % of the compressive strength Also, comparison between the experimental shear strength and ACI 318-11 shear provisions shows this equation overestimates the shear strength of the two beams (one for the CC and one for the SCC mix) for low longitudinal reinforcement ratios, which has also been reported by other researchers (e.g., Collins and Kuchma 1999).

3.1 Cracking and Failure Mode

In terms of crack morphology, crack progression, and load–deflection response, the behavior of the SCC and CC beams was virtually identical. All of the beams failed in shear. For the beams without shear reinforcing, failure occurred when the inclined flexure-shear crack penetrated to the compression zone of the beam near the loading plate prior to yielding of the longitudinal reinforcement, as observed in Fig. 3. For the beams with shear reinforcing, failure occurred when the stirrups crossing the critical flexure-shear crack reached yield. Based upon data collected from the strain gauges, none of the longitudinal reinforcement reached yield at failure, as expected, all of the stirrups yielded.

Fig. 3
figure 3

Crack pattern of the beams at shear failure.

Crack progression in the beams began with the appearance of flexural cracks in the maximum moment region, followed by additional flexural cracks forming between the load and support regions as the load was increased. Upon further increasing the applied load, the majority of the flexural cracks developed vertically and, after that, inclined flexure-shear cracks began to appear. As the load increased further, the inclined cracks progressed both upward toward the applied load plate and horizontally along the longitudinal reinforcement toward the support (see Fig. 3). Figure 3 offers a direct visual comparison of the crack shape and distribution at failure for both the SCC beams.

Figure 4 shows the load–deflection behavior for the beams with different longitudinal reinforcement ratios (the deflection was measured at midspan). Before the first flexural cracks occurred (point A), all of the beams displayed a steep linear elastic behavior. After additional application of load, the beams eventually developed the critical flexure-shear crack, which resulted in a drop in load and redistribution of the internal shear (point B for example). After this redistribution, the beams were able to support additional load until reaching failure. As expected, sections with a higher percentage of longitudinal reinforcement had a higher shear capacity, which can be attributed to a combination of additional dowel action (Taylor 1972, 1974), tighter shear cracks and thus an increase in aggregate interlock, and a larger concrete compression zone due to a downward shift of the neutral axis.

Fig. 4
figure 4

Load-deflections of the beams.

3.2 Shear Provisions of Selected Standards

In the following section, the experimental shear strengths of the beams are compared with the shear provisions of the following standards: AASHTO LRFD-10, ACI 318-11, AS 3600-09, CSA-04, Eurocode 2-05, and JSCE-07.

Most design codes consider the shear strength of reinforced concrete beams as consisting of two parts—a concrete contribution and a steel contribution—with the total capacity of the section equal to the sum of these two values. Although the actual behavior consists of a very complex interaction of these aspects, the codes treat each contribution independently, with one equation given for the concrete contribution and another equation for the steel contribution.

Some codes specify more than one method to evaluate the shear capacity of a reinforced concrete beam, such as the truss method, modified compression field theory (MCFT), and strut and tie methods. In this study, the most common method of each code was compared to the experimental shear strength determined from the testing program.

With regard to the concrete contribution to shear strength, the design code provisions are generally a function of the following considerations:

  • Web width (b w or b v );

  • Effective depth, where some provisions use effective flexural depth (d), but some use effective shear depth [dv = max (0.72 h, 0.9 days)];

  • Compressive strength of the concrete, where some provisions use the square root of the compressive strength of concrete and others use the cube root;

  • Longitudinal reinforcement ratio, where some provisions use longitudinal reinforcement ratio with a power of one, while others use the cube root, but AASHTO LRFD-10 and CSA-04 use strain of the longitudinal steel and concrete, respectively.

  • All of the design provisions require shear reinforcement in the event that the applied shear exceeds the concrete contribution. However, the codes vary as to at what point that shear reinforcement is required. For example, ACI 318-11 requires shear reinforcement when the applied shear exceeds one-half of the concrete contribution. The Eurocode 2-05 is the one exception that requires a minimum amount of shear reinforcement in all members.

Table 5 presents the minimum shear reinforcement requirements as well as the maximum spacing limitations for shear reinforcement of the aforementioned standards. As can be seen, the largest value for minimum shear reinforcement is computed by the AASHTO LRFD-10 equation and the lowest value for spacing between shear reinforcement is calculated by the ACI 318-08 and Japanese standards. The stirrups in the test beams, A vmin  = 142 mm2 (2#10) and S = 180 mm, met all of these standard requirements.

Table 5 Avmin and s for the selected codes.

3.2.1 Comparison of Test Results with Shear Provisions of the Standards

For the comparison of test results to the code predicted values, all of the safety factors of the standards were set equal to one and all ultimate moments and shear forces were calculated without load factors.

Table 6 presents the ratio of experimental-to-code predicted capacity (V test /V code ) for each of the selected design standards. In general, for a given standard, the ratios are very consistent between the two concrete types for beams with the same amount of longitudinal reinforcement. For example, for the AASHTO code, the ratios for the NS-6 CC beams are 1.12 and 1.22, while the ratios for the NS-6 SCC beams are 1.08 and 1.17. Overall, for the beams without stirrups, the ratios range from 0.73 to 1.72 for CC and 0.77–1.55 for SCC. Furthermore, the average of the ratios for each standard was slightly higher for the SCC compared to the CC for beams without stirrups. With regard to the ratios that fell below 1.0—an unconservative result—this situation has been observed by other researchers (Collins and Kuchma 1999), and it is important to note that the majority of standards do not allow sections without stirrups unless the factored shear force is significantly less than the concrete capacity in shear.

Table 6 V test /V code for the selected codes.

For the beams with stirrups, the ratios were in even better agreement between the two concrete types, most likely due to the greater predictability of the stirrup capacity portion of the shear strength, with ratios ranging from 1.18 to 1.43 for the CC and 1.10–1.51 for the SCC. For the beams with stirrups, the average of the ratios for each code was slightly higher for the CC compared to the SCC. Most importantly, the ratios were all well above 1.0, indicating a conservative result for the code predicted values.

As expected, the AASHTO LRFD-10 and CSA-04 results were very close (since both are based on the MCFT) and they overestimated the shear strength of the beams in some cases, although with a high COV. The MCFT was developed by researchers at the University of Toronto (Vecchio and Collin 1986). The basis of the MCFT is to determine the point at which the diagonal compressive struts fail and to determine the angle of the struts. From the crushing strength and the angle, the contribution of the concrete, Vc, can be found.

ACI 318-11 overestimated the capacity only for one of the low longitudinal reinforcement ratios (one for the CC and one for the SCC mix), which has also been reported by other researchers (e.g., Collins and Kuchma 1999).

3.3 Comparison of Test Results with Shear Test Database

The four key parameters that affect concrete contribution to shear strength include depth of member or size effect (d), shear span to depth ratio (a/d), compressive strength of concrete (f c ′), and longitudinal reinforcement ratio (ρ) (Reineck et al. 2003). To evaluate the effect of the aforementioned parameters on shear strength of the beams, the results of this study were compared with the wealth of shear test data available in the literature for CC (Reineck et al. 2003). Figure 5a–d presents the shear stress versus d, a/d, f c ′, and ρ, respectively. Given the significant scatter of the database of previous shear test results, it is somewhat difficult to draw definitive conclusions on the current test values. Nonetheless, visually, Fig. 5 seems to indicate that the CC and SCC test results fall within the central portion of the data and follow the same general trend of the database. Furthermore, statistical analysis of the data indicates that the test results fall within a 95 % confidence interval of a nonlinear regression curve fit of the database. This result indicates that for the specimens tested, the SCC shear strength is comparable with the shear strength of CC.

Fig. 5
figure 5

Comparison of test results of this study with shear database (Reineck et al. 2003).

Figure 5e shows normalized shear strength (based on square root of compressive strength of concrete) versus longitudinal reinforcement ratio for the beams of this study and the shear database. As mentioned above, since span-to-depth ratio plays a significant role in the shear strength of beams, Fig. 5f shows the normalized shear strength for the beams of this study with the portion of the database that had similar span-to-depth ratios of the current study [span-to-depth ratio ±5 % (2.9–3.4)]. Similar to Fig. 5a–d, it can be seen from Fig. 5e, f that the test results of this current study are also within a 95 % confidence interval of a nonlinear regression curve fit of the shear database and subset of that. As a result, it would again appear that the SCC beams show comparable shear strength with the CC beams.

3.4 Statistical Data Analysis

Statistical tests (both parametric and nonparametric) were used to evaluate whether there is any statistically significant difference between the shear strength of the SCC and the CC beams.

3.4.1 Parametric Test

The paired t test is a statistical technique used to compare two population means. This test assumes that the differences between pairs are normally distributed. If this assumption is violated, the paired t test may not be the most powerful test. The hypothesis for the paired t test is as follows:

  • Ho: The means of the shear capacity of the SCC and the CC beams are equal.

  • Ha: The means of the shear capacity of the SCC and the CC beams are not equal.

The statistical computer program Minitab 15 was employed to perform these statistical tests. Both Kolmogorov–Smirnov and Anderson–Darling tests showed the data—the differences between the shear capacities of the SCC and the CC beams—follows a normal distribution. Therefore, the paired t tests could be performed. The result of the paired t test showed that the p value was 0.359 (>0.05). This confirms the null hypothesis at the 0.05 significance level. In other words, there is no statistically significant difference between the means of the normalized shear capacity of the SCC and CC beams tested in this investigation.

3.4.2 Nonparametric Test

Unlike the parametric tests, nonparametric tests are referred to as distribution-free tests. These tests have the advantage of requiring no assumption of normality, and they usually compare medians rather than means. The Wilcoxon signed-rank test is usually identified as a nonparametric alternative to the paired t test. The hypothesis for this test is the same as those for the paired t test. The Wilcoxon signed rank test assumes that the distribution of the difference of pairs is symmetrical. This assumption can be checked; if the distribution is normal, it is also symmetrical. As mentioned earlier, the data follows normal distribution and the Wilcoxon signed ranks test can be used. The p value for the Wilcoxon signed rank was 0.363 (>0.05), that confirmed the null hypothesis at the 0.05 significance level. Interestingly, the p values for both the paired t tests (parametric test) and the Wilcoxon signed rank test (nonparametric test) are very close to each other.

Overall, results of the statistical data analyses showed that there is no statistically significant difference between the means of the normalized shear capacity of the SCC and CC beams.

3.5 Comparison of Longitudinal Reinforcement Strains and Diagonal Shear Crack Angle from Experiment with AASHTO LRFD

According to the AASHTO LRFD-10 standard, strain in the longitudinal tension reinforcement can be determined by

ε s = ( | M u | d v + | V u | ) E s A s
(2)

where A s is the area of non prestressed tension reinforcement (m2), d v is the effective shear depth (m), E s is the modulus of elasticity of reinforcing bars (MPa), M u is the factored moment at section (N.m), V u is the factored shear force at section (N), ε s is the strain in nonprestressed longitudinal tension reinforcement (m/m).

Table 7 presents the tensile strain in the longitudinal tension reinforcement at the quarter-point of the span (middle of the shear test region) obtained from both the experiments (strain gauges) and also the AASHTO LRFD-10 equation. This AASHTO LRFD-10 equation underestimates the strain for the SCC beams. The measured strains are based on the installed strain gages. Even with the potential for slight inaccuracies in the strain gage readings due to localized cracking and the slight reduction in cross section required for mounting the gages, the measured readings offer a valuable basis of comparison with the AASHTO LRFD-10 equation. The concrete component of shear (V c ) is the sum of the resistance due to three shear mechanisms: uncracked concrete, aggregate interlock, and dowel action. Higher strain in the tension reinforcement means more dowel action and since no significant difference was observed in the shear crack patterns compared with CC beams, it may be concluded that the SCC beams have lower aggregate interlock. Authors suggest push-off specimen tests for future research to evaluate aggregate interlock between the CC and SCC mix designs.

Table 7 Comparison of longitudinal reinforcement strain and diagonal shear crack angle from experiment and AASHTO-LRFD equation.

The angle of the critical shear crack is an important design parameter in the AASHTO LRFD-10 sectional design method. Although it is difficult to determine precisely as it is open to interpretation. The procedure used to determine this angle consisted of measuring the angle of a portion of the critical shear crack between two reference points, with the points corresponding to right after crossing the alignment of the longitudinal reinforcement and before entering the compression zone (Fig. 6). The diagonal shear crack angle is calculated in AASHTO LRFD-10 by Eq. (3).

Fig. 6
figure 6

Diagonal shear crack angle.

θ = 29 + 3500 ε s
(3)

where θ is angle of inclination of diagonal compressive stresses (degrees).

Table 7 compares measured diagonal shear crack angle from the test specimens with the calculated angle from the AASHTO LRFD-10 equation. As it can be seen from Table 7, the AASHTO LRFD-10 equation accurately predicted the diagonal shear crack angle for the SCC beams with stirrup, but it underestimated for the beams without stirrup.

4 Conclusions

To evaluate the shear strength of chemically-based SCC, 16 full-scale CC and SCC beams constructed with different longitudinal reinforcement ratios were tested to failure. Based on the results of this study, the following conclusions are presented:

  • In terms of crack morphology, crack progression, and load–deflection response, the behavior of the SCC and CC beams was virtually identical.

  • In general, for a given standard, the ratios of experimental-to-code predicted capacity are very consistent between the two concrete types for beams with the same amount of longitudinal reinforcement.

  • For beams without stirrups, the ratios of experimental-to-code predicted values for each standard were slightly higher for the SCC compared with the CC.

  • For beams with stirrups, the ratios of experimental-to-code predicted values for each standard were slightly higher for the CC compared with the SCC.

  • Statistical data analyses (parametric and non-parametric) showed that there is no statistically significant difference in the normalized shear strength of the SCC and CC beams tested in this study.

  • The SCC and CC test results fall within a 95 % confidence interval of a nonlinear regression curve fit of the CC shear test database.

  • The AASHTO LRFD estimation of the longitudinal tensile strain of the reinforcements is less than the actual strain for the SCC beams. This higher strain in the reinforcements can be attributed to higher dowel action. Since both the SCC and the CC beams had the same crack patterns, it may be inferred that the SCC beams have lower aggregate interlock compared with the CC beams.

  • The AASHTO LRFD equation predicts the diagonal shear crack angle of both the CC and SCC beams very well for beams with shear reinforcement, but it underestimates for the beams without shear reinforcement.

In particular, future research should focus on aggregate interlock of SCC beams constructed with a chemically-based mix.

Due to the limited nature of the data set regarding aspect ratio, mix designs, aggregate type and content, etc. investigated, these results cannot be generalized and the researchers recommend further testing to increase the database of SCC test results.

From a financial perspective, the SCC mixes cost approximately 3 % more than the CC mixes due to the cost of the chemical admixtures. The structural benefits of this type of approach to SCC would need to be balanced against this additional material cost.

References

  • American Concrete Institute ACI Committee. (2007). Self-consolidating concrete ACI 237R-07. Farmington Hills, MI: American Concrete Institute.

    Google Scholar 

  • Bendert, D. A., & Burgueño, R. (2006a). Report on the experimental evaluation of prestressed box beams for SCC demonstration bridge. Research Report CEE-RR-2006-01, Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI.

  • Bendert, D. A., & Burgueño, R. (2006b). Report on the production of prestressed box beams for SCC demonstration bridge. Research Report CEE-RR-2006-02, Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI.

  • Burgueño, R., & Till, R. (2005). Special provision for production of prestressed beams with self-consolidating concrete. Internal Report, Michigan Department of Transportation, Lansing, MI.

  • Choulli, Y. & Mari, A. R. (2005). Shear Behaviour of full scale prestressed I beams made with Self Compacting Concrete: Proceedings Second North American Conference on the Design and Use of Self-Consolidating Concrete and the Fourth International RILEM Symposium on Self-Compacting Concrete (CD-ROM). Chicago, IL.

  • Collins, M. P., & Kuchma, D. (1999). How safe are our large, lightly reinforced concrete beams, slabs, and footings? ACI Structural Journal,96(4), 482–490.

    Google Scholar 

  • Daczko, J., & Vachon, M. (2006). “Self consolidating concrete (SCC), significance of tests and properties of concrete and concrete-making materials,” STP 169D (pp. 637–645). West Conshohocken, PA: ASTM International.

    Book  Google Scholar 

  • Das, D., Kaushik, S. K., Gupta, V. K. (2005). Shear resistance of self-compacting concrete: Proceedings Second North American Conference on the Design and Use of Self-Consolidating Concrete and the Fourth International RILEM Symposium on Self-Compacting Concrete (CD-ROM). Chicago, IL.

  • Dymond, BZ. (2007). Shear strength of A PCBT-53 girder fabricated with lightweight, self-consolidating concrete. MS Thesis, Virginia Tech, Blacksburg, VA.

  • Dymond, BZ., Roberts-Wollmann, CL., & Cousins, T. E. (2009). Shear strength of a PCBT-53 girder fabricated with lightweight, self-consolidating concrete. Rep. No. 09-CR11, Virginia Transportation Research Council (VTRC): Charlottesville, VA.

  • Dymond, B. Z., Roberts-Wollmann, C. L., & Cousins, T. E. (2010). Shear strength of a lightweight self-consolidating concrete bridge girder. Journal of Bridge Engineering ASCE,15(5), 615–618.

    Article  Google Scholar 

  • Hassan, A. A. A., Hossain, K. M. A., & Lachemi, M. (2008). Behavior of full-scale self-consolidating concrete beams in shear. Cement and Concrete Composites,30(7), 588–596.

    Article  Google Scholar 

  • Hassan, A. A. A., Hossain, K. M. A., & Lachemi, M. (2010). Strength, cracking and deflection performance of large-scale self-consolidating concrete beams subjected to shear failure. Engineering Structures,32(5), 1262–1271.

    Article  Google Scholar 

  • Okamura, H. (1997). Self-compacting high-performance concrete, Concrete International, pp. 50–54.

  • Ozawa, K., Maekawa, K., Kunishima, M., & Okamura, H. (1989). Development of high performance concrete based on the durability design of concrete structures: Proceedings of the Second East-Asia and Pacific Conference on Structural Engineering and Construction (EASEC-2). Vol. 1, pp. 445–450.

  • Reineck, K. H., Kuchma, D. A., Kim, K. S., & Marx, S. (2003). Shear database for reinforced concrete members without shear reinforcement. ACI Structural Journal,100(2), 240–249.

    Google Scholar 

  • Taylor, H. P. J. (1970). Investigation of the forces carried across cracks in reinforced concrete beams in shear by interlock of aggregate. Cement and Concrete Association, London, Technical report 42.447.

  • Taylor, H. P. J. (1972). Shear strength of large beams. Journal of the Structural Division ASCE,98(ST11), 2473–2489.

    Google Scholar 

  • Taylor, H. P. J. (1974). The fundamental behavior of reinforced concrete beams in bending and shear American Concrete Institute, Shear in Reinforced Concrete, SP-42, pp. 43–77.

  • Vecchio, F. J., & Collin, M. P. (1986). The modified compression field theory for reinforced concrete elements subjected to shear. ACI Structural Journal,83(2), 219–223.

    Google Scholar 

  • Wilson, N. D., Kiousis, P. (2005) High-strength SCC in shear: Proceedings Second North American Conference on the Design and Use of Self-Consolidating Concrete and the Fourth International RILEM Symposium on Self-Compacting Concrete. Chicago, IL.

Download references

Acknowledgments

The authors gratefully acknowledge the financial support provided by the BASF and the National University Transportation Center at Missouri University of Science and Technology (Missouri S&T). The authors would also like to thank the support staff in the Department of Civil, Architectural and Environmental Engineering and Center for Infrastructure Engineering Studies at Missouri S&T for their efforts. The conclusions and opinions expressed in this paper are those of the authors and do not necessarily reflect the official views or policies of the funding institutions.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mahdi Arezoumandi.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Reprints and permissions

About this article

Cite this article

Arezoumandi, M., Volz, J.S. An Experimental Study on Shear Strength of Chemically-Based Self-Consolidating Concrete. Int J Concr Struct Mater 7, 273–285 (2013). https://doi.org/10.1007/s40069-013-0052-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40069-013-0052-1

Keywords