Skip to main content

Table 3 Results, sample content at start, middle and end of truck discharge of steel fiber reinforced concrete, 250 g/10 l = 25 kg/m3.

From: Investigation of Fiber Distribution in Concrete Batches Discharged from Ready-Mix Truck

Truck load no.

Start kg/m3

Middle kg/m3

End kg/m3

Average kg/m3

% of added

1

216.0

207.0

235.0

219.3

87.7

2

253.0

205.0

300.0

252.7

101.1

3

247.0

227.0

242.0

238.7

95.5

4

242.0

250.0

241.0

244.3

97.7

5

256.0

198.0

356.0

270.0

108.0

6

247.0

196.0

265.0

236.0

94.4

7

242.0

246.0

254.0

247.3

98.9

8

239.0

210.0

261.0

236.7

94.7

9

264.0

251.0

216.0

243.7

97.5

10

249.0

237.0

244.0

243.3

97.3

11

258.0

244.0

216.0

239.3

95.7

12

238.0

225.0

307.0

256.7

102.7

13

230.0

240.0

255.0

241.7

96.7

14

258.0

228.0

336.0

274.0

109.6

15

242.0

285.0

192.0

239.7

95.9

Average

245.4

229.9

261.3

245.6

98.2

Portions of the amounts added to the batch

98.2 %

92.0 %

104.5 %

98.2 %

98.2%