Fig. 10From: Experimental and Numerical Assessment of the Service Behaviour of an Innovative Long-Span Precast Roof ElementTest instrumentation: counter-weight bundles of steel bars (a), edge ram, load cell and load repartition beam (b), central ram and load cell (c), end short-stroke LVDT (d), central long-stroke LVDT (e), wing opening LVDTs (f).Back to article page