Skip to main content

Table 2 Main test parameters and properties of precast concrete interior connections.

From: Experimental Cyclic Behavior of Precast Hybrid Beam-Column Connections with Welded Components

Specimen

α

Lc (mm)

Lw (mm)

ρw (%)

sh/db

Lu (mm)

C (%)

CE (%)

SP1

2.0

450

340

0.52

5.6

N.A.

0.31

0.49

SP2

1.5

350

250

0.52

5.6

N.A

0.19

0.35

SP3

1.2

300

200

0.52

5.6

N.A

0.196

0.37

SP1-R

2.0

450

340

0.52

5.6

5 db

0.19

0.35

SP3-R

1.2

300

200

1.0

4.2

10 db

0.196

0.34