Skip to main content

Table 4 The experimental parameters of pullout test.

From: Pull-Out Behaviour of Hooked End Steel Fibres Embedded in Ultra-high Performance Mortar with Various W/B Ratios

Series

Medium

Embedded length(mm)

Pmax

(N)

peak (mm)

Wtotal

(N/mm)

σmax/f y

σmax

τ eq

τ av

(−)

 

(N/mm2)

 

3DH1-U1-LE10

 

10

216

0.61

753

0.67

909

8.72

12.51

3DH1-U1-LE15

UHPM1

15

233

1.02

1153

0.73

980

5.93

8.90

3DH2-U1-LE10

 

10

475

0.40

2595

0.64

747

18.36

16.85

3DH2-U1-LE30

 

30

510

1.67

5443

0.69

802

4.28

12.14

3DH1-U2-LE10

 

10

196

0.48

664

0.61

825

7.69

11.33

3DH1-U2-LE15

UHPM2

15

195

0.85

922

0.61

821

4.74

7.58

3DH2-U2-LE10

 

10

430

1.08

1848

0.58

676

13.08

15.29

3DH2-U2-LE30

 

30

429

1.36

5027

0.58

675

3.95

10.16

3DH1-U3-LE10

 

10

185

0.49

598

0.58

779

6.93

10.77

3DH1-U3-LE15

UHPM3

15

204

0.73

908

0.63

860

4.67

7.82

3DH2-U3-LE10

 

10

342

0.86

1706

0.46

539

12.07

12.14

3DH2-U3-LE30

 

30

423

1.58

4120

0.57

665

3.23

9.95