Skip to main content

Table 6 Test results of concrete carbonation depth (unit: mm).

From: Performance Based Evaluation of Carbonation Resistance of Concrete According to Various Curing Conditions from Climate Change Effect

Wind speed

Sunlight exposure time

2

4

6

8

0

5.2

6.4

6.5

6.9

2

6.4

7.0

7.7

7.9

4

8.3

8.5

8.6

8.6

6

8.6

8.5

9.1

8.9

  1. * Thermo-hydrostatic curing: 0.8, ** wet curing: 0.6, *** air dry curing: 4.9.