Skip to main content

Table 2 Tested tensile strength of the GFRP hybrid bar.

From: Response of Glass Fiber Reinforced Polymer (GFRP)-Steel Hybrid Reinforcing Bar in Uniaxial Tension

 

D13

D13 (D10)

D16 (D10)

D16 (D13)

D19

D19 (D10)

D19 (D13)

D19 (D16)

1

1108.5

649.7

768.3

591.5

957.0

893.1

561.2

483.0

2

1125.1

704.0

818.8

611.0

872.6

910.2

576.0

498.4

3

1112.8

680.0

794.3

613.1

924.7

845.2

534.7

438.4

4

1174.9

805.6

611.6

858.2

854.6

535.3

490.9

5

1091.6

799.9

606.2

942.2

922.1

413.5

473.6

6

1108.5

805.8

634.1

865.7

970.0

536.7

472.7

Average tensile strength (MPa)

1120.2

677.9

798.8

611.3

903.4

899.2

526.2

476.2

Standard deviation (MPa)

24.4

22.2

15.5

12.5

39.3

42.0

52.7

19.2