Skip to main content

Table 2 Properties of GFRP bars.

From: Bond Strength of GFRP Bars Embedded in Engineered Cementitious Composite using RILEM Beam Testing

Bar type

Bar size (D)

Nominal bar diameter (dn) (mm)

Actual bar diameter (db) (mm)

Modulus of elasticity (GPa)

Tensile strength (MPa)

Ultimate tensile load (kN)a

Tensile strain (%)

LM

12

12.7

14.4

42.5 ± 2.5

1000

127

2.35

LM

16

15.9

17.3

42.5 ± 2.5

940

187

2.21

LM

19

19.1

20.5

42.5 ± 2.5

940

269

2.21

HM

12

12.7

15.5

65.6 ± 2.5

1312

166

2.00

HM

16

15.9

18.8

62.6 ± 2.5

1184

235

1.89

HM

19

19.1

21.7

63.7 ± 2.5

1105

317

1.73

  1. aCalculated based on nominal bar diameter; Actual bar diameter (db) with sand coating.