Skip to main content

Table 3 Dimensions of beam specimens.

From: Bond Strength of GFRP Bars Embedded in Engineered Cementitious Composite using RILEM Beam Testing

Beam type

Type A

Type A

Type B

Bar size, D (mm)

12

16

19

Nominal bar, dn (mm)

12.7

15.9

19.1

Embedment lengths, 5D/7D/10D (mm)

60/84/120

80/112/160

95/133/190

Thickness of concrete blocks (mm)

100

100

150

Depth of concrete blocks (mm)

180

180

240

Length of concrete blocks (mm)

375

375

600

Distance between concrete blocks (mm)

50

50

60

Total length of beams (mm)

800

800

1260

Length of bars tested (mm)

1000

1000

1500

Distance between centre-line of bar and centerline of hinge (mm)

100

100

150

Distance between centre-line of bar and underside of beam (mm)

50

50

50

Spacing of the loads (mm)

150

150

200

Spacing of the bearing supports (mm)

650

650

1100