Skip to main content

Table 3 Student t test analysis for compressive strength test results based on the exposure to different number of cycles.

From: Thermal Stability of Latex Modified Mortars Containing CNTs

Sample type

Type of testing

No. of cycles

t Test results

Level of difference

Control

F_T

0 cycles

1.00

No difference

150 cycles

0.02

Significant difference

300 cycles

0.04

Significant difference

T_F

0 cycles

1.00

No difference

150 cycles

0.54

No difference

300 cycles

0.03

Significant difference

0.5% CNTs

F_T

0 cycles

1.00

No difference

150 cycles

0.05

Significant difference

300 cycles

0.04

Significant difference

T_F

0 cycles

1.00

No Difference

150 cycles

0.49

No difference

300 cycles

0.99

No difference

1.0% CNTs

F_T

0 cycles

1.00

No difference

150 cycles

0.00

Significant difference

300 cycles

0.01

Significant difference

T_F

0 cycles

1.00

No difference

150 cycles

0.17

No difference

300 cycles

0.96

No difference

1.5% CNTs

F_T

0 cycles

1.00

No difference

150 cycles

0.06

Significant difference

300 cycles

0.00

Significant difference

T_F

0 cycles

1.00

No difference

150 cycles

0.02

Significant difference

300 cycles

0.93

No difference