Skip to main content

Table 3 Measured corrosion levels, exposure days, permanent load during corrosion and ultimate applied load on span centre at failure.

From: Ultimate Capacity of Corroded Statically Indeterminate Reinforced Concrete Members

 

Specimen

Exposure time (days)

Steel loss (% top/bottom reinforcement)

Permanent load (kN)

Ultimate load (kN)

Loss of capacity (%)

Group 1a

G1_2P

56

6/14

16.50

24.50

29

G1_P

6/12

6.74

24.75

29

G1_SW

9/11

0.00

11.40

67

Group 2

G2_2P

42

6/15

17.70

25.75

26

G2_SW

6/10

0.00

21.00

39

G2_P

7/15

8.34

24.75

29

Group 3

G3_SW

100

15/15

0.00

21.80

37

G3_P

17/20

8.47

21.00

39

G3_2P

10/24

17.50

17.50b

56

Group Uncorroded

GR_2P

–/–

 

31.60

GR_P

 

36.59

GR_SW

 

36.42

  1. aBeams without lateral strengthening.
  2. bBeam failed under permanent load.