Skip to main content

Table 2 Details of specimens.

From: Experimental Investigation on Damage Behavior of Polypropylene Fiber Reinforced Concrete under Compression

No.

Specimens

Vpf (%)

lpf/dpf

fcu (MPa)

fst (MPa)

1

PF000

–

–

47.53

2.75

2

PFA05

0.05

167

50.62

3.24

3

PFA10

0.10

167

49.43

3.35

4

PFA15

0.15

167

48.84

3.47

5

PFA20

0.20

167

45.22

3.17

6

PFB10

0.10

280

51.26

3.42

7

PFB15

0.15

280

47.45

3.68

8

PFC10

0.10

396

50.14

3.55

9

PFC15

0.15

396

50.65

3.58