Table 7 Summary of the testing data.

From: Performance Evaluation of CFRP Reinforced Concrete Members Utilizing Fuzzy Technique

Specimen

Ft (MPa)

εt

Eg (MPa)

H*

26.61

0.0023

− 25,974**

H2-I 0

32.63

0.003

12,810.59

H2-I 1

31.28

0.0033

2527.83

H2-I 2

30.67

0.0028

− 13,138.2**

H2-I 3

31.43

0.0027

− 24,890.9**

H2-I 4

30.48

0.0027

− 34,703.1**

H2-I 1-T

34.86

0.0032

11,652.96

H2-I 1-A

35.33

0.0037

5081.056

H2-I 1-B

37.02

0.0036

22,674.68

N*

21.13

0.0018

− 19,276.4**

N2-I0

25.70

0.0031

3156.05

N2-II3

26.66

0.0031

2852.00

N3-II1

26.83

0.0039

9814.00

N3-II3

25.87

0.0035

4602.43

N3-I1

26.57

0.0034

6210.99

N3-I1-T

29.07

0.0036

8967.37

N3-I0-A

28.59

0.00378

5697.24

N3-I1-B

29.81

0.0037

7984.13

  1. *H and N are reference specimens.
  2. **(−) symbol means ‘descending’ at Fig. 1.