Skip to main content

Table 3 Test results for compressive strength of concrete.

From: Thermal and Mechanical Behaviors of Concrete with Incorporation of Strontium-Based Phase Change Material (PCM)

Mixture

7 day

28 day

91 day

fcu (MPa)

S.D. (MPa)

fcu (MPa)

S.D. (MPa)

fcu (MPa)

S.D. (MPa)

OPC

30.3

1.28

34.0

0.89

37.2

1.11

OPC + PCM

26.9

1.46

32.5

1.51

37.8

0.56

LHC

19.0

0.52

37.5

1.59

49.8

1.39

LHC + PCM

16.9

0.47

32.4

1.86

43.3

1.81

CBF

19.1

0.62

33.6

0.55

42.5

1.16

CBF + PCM

18.6

0.56

32.5

0.97

40.2

1.02

  1. S.D. standard deviation.