From: Effect of Impact Load on Splice Length of Reinforcing Bars
Specimen groups | Dimensions (mm × mm) | Longitudinal bars | Transverse bars | Splice length (mm) | Concrete strength (MPa) | Hammer mass (kg) | Drop height (m) | Ps/PM |
---|---|---|---|---|---|---|---|---|
S-18-300-L | 250 × 300 | D18 | D8@100 | 300 | 37.72 | 272.3 | 3.15/6.30/12.60 | 2.38 |
597.3 | 5.74 | |||||||
S-18-400-L | 400 | 37.96 | 272.3 | 3.15/6.30/12.60 | 2.38 | |||
597.3 | 5.74 | |||||||
S-18-300 | 300 | 31.16 | 532.3 | 1.58/3.15/4.73 | 2.34 | |||
857.3 | 1.96 | |||||||
S-18-400 | 400 | 30.01 | 532.3 | 1.58/3.15/6.30 | 2.34 | |||
857.3 | 1.96 | |||||||
S-25-300 | D25 | 300 | 34.62 | 532.3 | 1.58/3.15/4.73 | 1.38 | ||
857.3 | 1.96 | |||||||
S-25-400 | 400 | 32.77 | 532.3 | 1.58/3.15/6.30 | 1.38 | |||
857.3 | 1.96 |