Skip to main content

Table 8 Cracking indicators of cement mortar with CNTs (W/C = 0.3).

From: Autogenous Shrinkage and Crack Resistance of Carbon Nanotubes Reinforced Cement-Based Materials

CNTs content/wt%

Semi-closed experiment

Closed

Cracking time/h

Cracking strain/10−6

Cracking time/h

Cracking strain/10−6

0.00

101.3

− 150

212.2

− 142

0.05

98.3

− 110

223.2

− 133

0.10

102.3

− 115

310.2

− 138

0.15

99.8

− 107

248.5

− 121