Skip to main content

Table 4 Verification of specimen temperature results.

From: Thermal Resistance of Insulated Precast Concrete Sandwich Panels

Specimen Ambient Surface Temperature (°C) Cold face Temperature (°C)
Exp FEM Error (%) Exp FEM Error (%)
P0 59.00 61.07 3.5 31.80 32.51 2.2
P2 65.15 66.14 1.5 27.60 27.50 0.4
P3 67.45 67.45 0.0 26.96 26.13 3.1
P4 68.69 67.70 1.4 27.16 25.92 4.6
  1. Exp experimental, FEM finite element model