Table 1 Experimental UCS test results.

From: Experimental and Numerical Investigation of the Tensile Performance and Failure Process of a Modified Portland Cement

Water–cement rate

UCS (MPa)

E (GPa)

μ

0.35

63.1

11.8

0.23

0.42

54.3

9.9

0.21

  1. where E is the Young's modulus, μ is the Poisson's ratio