Table 9 Evaluation results for RC structures considering modified importance factor

From: Structural Safety Inspection of Reinforced Concrete Structures Considering Failure Probabilities of Structural Members

Floor

Member

Member level

Floor level

Importance factor of floor (KISTEC)

Importance factor of floor (Proposed method)

Structure level

KISTEC

Proposed method

KISTEC

Proposed method

4th floor

Column

A

C (4.77)

C (5.32)

0.30

0.41

D (7.40)

E (8.14)

Girder

C

Beam

A

Slab

D

3rd floor

Column

A

B (2.80)

B (2.90)

0.50

0.59

Girder

B

Beam

B

Slab

B

2nd floor

Column

B

B (2.98)

B (2.98)

0.70

0.83

Girder

B

Beam

A

Slab

B

1st floor

Column

A

D (7.83)

E (8.61)

0.90

0.90

Girder

E

Beam

E

Slab