Skip to main content

Table 3 Test specimen details

From: Experimental Evaluation of Shape Memory Alloy Retrofitting Effect for Circular Concrete Column Using Ultrasonic Pulse Velocity

Property

Value

Section diameter (mm)

300

Effective height (mm)

1500

Axial force (kN)

254.47

Compressive strength, \(f^{^{\prime}}_{c}\) (MPa)

35.6

Yield strength of longitudinal reinforcement (MPa)

458.5

Yield strength of tie reinforcement (MPa)

431.4

Longitudinal reinforcement ratio (%)

3.2

Volumetric ratio of tie reinforcement (%)

0.05