Freeze–thaw cycle | Measurement parameters | Test frequency | Termination of the test |
---|---|---|---|
GBT50082-2009 (2009); ASTM C666/C666M-15 (2015) | Mass loss rate: Eq. (1); Cube compressive strength (GB/T 50081–2019 (2019)) | 1/25 | Mass loss rate ≥ 5.0%; Subjected to 100 cycles |