Skip to main content

Table 6 Comparison of compression test results from each insulation system

From: Experimental Study of the Effect of Different Insulation Schemes on Fire Performance of FRP Strengthened Concrete: FIRECOAT and REALROCK

a) FIRECOAT

b) REALROCK

Specimen

Max. Load (N)

Max. Stress (N/mm2)

Specimen

Max. Load (N)

Max. Stress (N/mm2)

ID

No

ID

No

Ref.

Ref

1

945281.56

30.09

Ref.

Ref

1

945281.56

30.09

Ref-30

6

560723.19

17.85

Ref-30

5

543543.69

17.30

Ref-60

4

536824.31

17.09

Ref-60

3

536824.31

17.09

Set-1

CFRP

7

2705007.00

86.10

Set-1

CFRP

7

2705007.00

86.10

CFRP-30

12

1088490.13

34.65

CFRP-30

11

1249386.13

39.77

CFRP-60

10

576904.00

18.36

CFRP-60

9

576904.00

18.36

CFRP-T1-30

20

1137223.13

36.20

CFRP-T1-30

15

2167975.00

69.01

CFRP-T1-60

18

587583.44

18.70

CFRP-T1-60

13

599746.44

19.09

CFRP-T2-30

24

2371450.25

75.49

CFRP-T2-30

19

2235780.75

71.17

CFRP-T2-60

22

CFRP-T2-60

17

Set-2

GFRP

25

2143591.00

68.23

CFRP-T3-30

23

2338961.50

74.45

GFRP-30

30

734890.63

23.39

CFRP-T3-60

21

1676887.50

53.38

GFRP-60

28

603850.81

19.22

Set-2

GFRP

25

2143591.00

68.23

GFRP-T1-30

38

972557.44

30.96

GFRP-30

29

796519.69

25.35

GFRP-T1-60

36

675841.88

21.51

GFRP-60

27

661006.13

21.04

GFRP-T2-30

42

1636213.25

52.08

GFRP-T1-30

33

1408400.38

44.83

GFRP-T2-60

40

440795.81

14.03*

GFRP-T1-60

31

769538.19

24.50

     

GFRP-T2-30

37

1866427.63

59.41

     

GFRP-T2-60

35

1416181.88

45.08

     

GFRP-T3-30

41

2040831.63

64.96

 

GFRP-T3-60

39

1607563.50

51.17

  1. *Deviation due to specimen failure