Skip to main content

Table 3 Three-way splitting tensile strength of 3D-printed concrete specimens

From: Experimental Study on Structural Performance of Cast-in-Place Frame Printed Concrete Wall

Number

Peak pressure (kN)

Pressure-bearing area (mm2)

Splitting tensile strength (MPa)

Average splitting tensile strength (MPa)

Standard deviation

X-1

64.51

150 × 150

1.83

1.77

0.074

X-2

60.12

151 × 150

1.69

X-3

62.98

150 × 149

1.80

Y-1

66.57

150 × 150

1.88

1.77

0.11

Y-2

58.96

150 × 151

1.66

Y-3

62.15

151 × 150

1.76

Z-1

112.31

149 × 150

3.20

3.22

0.11

Z-2

118.12

149 × 151

3.34

Z-3

110.53

150 × 150

3.13