From: Experimental Study on Structural Performance of Cast-in-Place Frame Printed Concrete Wall
H (mm) | φ | |||
---|---|---|---|---|
1/1000 | 1/500 | 1/250 | 1/150 | |
(a) Specimen 1 column longitudinal bar strain data (\(\mu \varepsilon\)) | ||||
1200 | − 195.28 | − 520.49 | − 1030.52 | − 1626.37 |
850 | − 91.95 | − 267.83 | − 478.34 | − 860.58 |
400 | 106.31 | 308.15 | 539.2 | 1038.73 |
50 | 203.58 | 704.32 | 1540.37 | 3244.72 |
(b) Specimen 2 column longitudinal bar strain data (\(\mu \varepsilon\)) | ||||
1200 | − 105.07 | − 370.27 | − 722.16 | − 1576.02 |
850 | − 49.4 | − 198.4 | − 366.28 | − 730.58 |
400 | 50.91 | 230.05 | 446.05 | 924.6 |
50 | 125.3 | 603.58 | 1492.18 | 2680.47 |
(c) Specimen 3 column longitudinal bar strain data (\(\mu \varepsilon\)) | ||||
1200 | − 10.87 | − 59.46 | − 250.01 | − 640.73 |
850 | − 4.54 | − 23.84 | − 116.29 | − 264.28 |
400 | 5.22 | 27.48 | 123.57 | 309.7 |
50 | 19.11 | 159.46 | 567.93 | 1278.45 |