Skip to main content

Table 7 Comparison of the orientation efficiency factors for the control specimen

From: Steel Fiber Orientation Efficiency Factor Model for a Magnetically Treated Cement-Based Composite

Present study

Soroushian and Lee (1990)

Dupont and Vandewalle (2005)

Lee et al. (2014)

0.54(NM)

0.56(NSSM)

0.56(SSM)

0.54

0.51

0.63