From: Experimental Study on Modification of Grouting Material for Joints of Prefabricated Buildings
Group | Free expansion rate (%) | |||||||
---|---|---|---|---|---|---|---|---|
3d | 7d | 14d | 21d | 28d | 42d | 60d | 120d | |
BG | 0.0229 | 0.0569 | 0.1391 | 0.1029 | 0.076 | 0.0531 | 0.0317 | − 0.0117 |
E2C0R5 | 0.0324 | 0.0651 | 0.1413 | 0.1096 | 0.0847 | 0.0642 | 0.043 | − 0.0041 |
E2C2R5 | 0.0237 | 0.0721 | 0.1377 | 0.0998 | 0.0771 | 0.052 | 0.036 | − 0.0022 |
E2C5R5 | 0.0233 | 0.1193 | 0.1629 | 0.1148 | 0.0921 | 0.0698 | 0.049 | 0.0079 |
E2C7R5 | 0.0367 | 0.1333 | 0.165 | 0.1141 | 0.0881 | 0.0598 | 0.0404 | − 0.0052 |
E1C2R5 | 0.0129 | 0.0547 | 0.1199 | 0.0825 | 0.0624 | 0.0304 | 0.017 | − 0.0112 |
E3C2R5 | 0.0393 | 0.0804 | 0.1449 | 0.1159 | 0.099 | 0.067 | 0.048 | 0.0040 |
E2C2R7 | 0.0271 | 0.0775 | 0.1388 | 0.1001 | 0.0814 | 0.054 | 0.037 | 0.0003 |
E2C2R10 | 0.0419 | 0.1105 | 0.1855 | 0.1245 | 0.1121 | 0.0938 | 0.07 | 0.0229 |
E2C2R15 | 0.0395 | 0.105 | 0.1852 | 0.1221 | 0.1105 | 0.0919 | 0.068 | 0.0229 |