From: Compressive Behavior of Concrete Containing Glass Fibers and Confined with Glass FRP Composites
Material | Mix# 1(8.5 MPa) | Mix# 2 (16 MPa) | Mix# 3 (25 MPa) |
---|---|---|---|
Cement | 200 kg/m3 | 300 kg/m3 | 400 kg/m3 |
Sand | 853 kg/m3 | 810 kg/m3 | 773 kg/m3 |
Coarse aggregate | 853 kg/m3 | 520 kg/m3 | 496 kg/m3 |
Fine aggregate | 481 kg/m3 | 520 kg/m3 | 496 kg/m3 |
Water | 100 kg/m3 | 132 kg/m3 | 163 kg/m3 |
Superplasticizer | As required | As required | As required |
Compressive strength MPa | 8.5 | 16 | 25 |