Skip to main content

Table 5 Test matrix

From: Realistic Evaluation of Reinforcement Bond Strength in Alkali-Activated Slag Concrete Exposed to Elevated Temperature

Ser

Specimens designation

Bar diameter (mm)

Temperature (°C)

Bond length to diameter (L/d)

1

D12-T25-4

12

25

4

2

D12-T300-6

 

300

6

3

D12-T600-8

 

600

8

4

D16-T25-8

16

25

8

5

D16-T300-4

 

300

4

6

D16-T600-6

 

600

6

7

D22-T25-6

22

25

6

8

D22-T300-8

 

300

8

9

D22-T600-4

 

600

4