Skip to main content

Study on the Fracture Toughness of Polypropylene–Basalt Fiber-Reinforced Concrete

Abstract

To study the hybrid effects of polypropylene fiber and basalt fiber on the fracture toughness of concrete, 13 groups of notched concrete beam specimens with different fiber contents and mass ratios were prepared for the three-point bending test. Based on acoustic emission monitoring data, the initiation cracking load and instability load of each group of specimens were obtained, and the fracture toughness parameters were calculated according to the double-K fracture criterion. The test results show that the basalt fiber-reinforced concrete has a greater increase in initial fracture toughness, and the toughness of coarse polypropylene fiber-reinforced concrete is more unstable. Moreover, after the coarse polypropylene fiber content reaches 6 kg/m3 and the basalt fiber content reaches 3 kg/m3, increasing the content will not significantly improve the fracture toughness of the concrete. The polypropylene–basalt fiber will produce positive and negative effects when mixed, and the mass ratio of 2:1 was optimal. Finally, the fitting analysis revealed that the fracture process of polypropylene–basalt fiber-reinforced concrete (PBFRC) can be objectively described by the bilinear softening constitutive curve improved by Xu and Reinhardt.

1 Introduction

With the emergence of large-span beams, super high-rise buildings and mass concrete structures, the requirements for concrete strength and ductility are increasing. Therefore, enhancing toughness and deformation performance have become an important problem to solve when the concrete strength increases, ductility decreases, and brittleness increases. It is one of the effective methods that adding fiber into concrete for improving the tensile strength, crack toughness and impact resistance (Abdallah et al., 2016, 2017; Guler et al., 2019). Compared with plain concrete, fiber-reinforced concrete can improve the stiffness of the components, enhance the ductility and cracking resistance, and have good frost resistance under the same conditions (Das et al., 2018; Liang et al., 2019b; Mudadu et al., 2018). Besides, it has been widely used in high-rise buildings, underground engineering structure, marine engineering and bridge engineering.

Studies have shown that adding different fibers can improve the toughness of concrete in different manners. Steel fiber improves the strength of concrete, and enhances fracture load and toughness in the fracture process (Abdallah et al., 2016; Chi et al., 2014). However, steel fiber has defects, such as high cost, self-importance, easy to rust, and poor workability. To eliminate the disadvantage of steel fiber, other fibers should be considered to adopt to replace the steel fiber. Polypropylene fiber is seen to possess some advantages compared to steel fiber: easy to work in concrete, better economy, light in weight, rarely corrode in concrete and resistant to aggressive chemicals (Deng et al. 2020b). Coarse polypropylene fiber (CF) has a larger size and a higher tensile strength of monofilament, which can inhibit the development of cracks in the later period, and is similar to steel fiber in terms of improving the durability and ductility of concrete (Buratti & Mazzotti, 2015; Buratti et al., 2011; Niu et al., 2018; Xia et al., 2013). Basalt fiber (BF) possesses excellent mechanical and physical properties, including high-temperature stability, superior tensile strength, good acid alkali-resistance, and excellent plastic deformation capacity, which is a new type of eco-friendly, cost-effective, high-performance, green and inorganic fiber (Branston et al., 2016; Jalasutram et al., 2017; Jiang et al., 2014; Wang et al., 2019). In addition, the basalt fiber has a small size and a large elastic modulus, which can inhibit the development of early micro cracks in the early stage.

Some researchers also believe that compared with the incorporation of single fiber, adding fibers with different elastic moduli, strengths and sizes into concrete can produce a positive hybrid effect in strengthening and toughening concrete, and more effectively improve the fracture toughness of concrete (Banthia et al., 2014; Kasagani & Rao, 2018; Wang et al., 2019). According to the previous researches, the fibers mixing ratio is the main factor affecting the mechanical properties (Abdallah et al., 2017; Liu, 2013), fracture parameters (Smarzewski, 2019; Soroushian et al., 1998) and flexural toughness (Smarzewski, 2018a, 2018b; Zhu et al., 2010) of concrete. In contrary, some results also show that polypropylene fibers and basalt fibers have no significant effect on the compressive strength (Ayub et al., 2014a, 2014b; Komlos et al., 1995) and flexural strength (Smarzewski, 2019) of concrete martix.

Nowadays, the hybrid basalt–polypropylene fiber-reinforced concrete has been widely concerned by researches. These studies usually focused on the fresh, mechanical, and durability properties (Arslan, 2016; Ayub et al., 2014a, 2014b; Jiang et al., 2016), impact-resistance behavior (Fu et al., 2018a, 2018b; Zhang et al., 2019), flexural toughness (Smarzewski, 2018a, 2018b) and fracture properties (Smarzewski, 2019, 2020) of hybrid basalt–polypropylene fiber-reinforced concrete. Besides, the polypropylene fibers used in their studies were fine fiber rather than the macro fiber. The coarse and long fibers determine the propagation of cracks and improve the toughness at the post-crack region (Afroughsabet & Ozbakkaloglu, 2015; Nataraja et al., 1999), while micro and short fibers bridge the micro-cracks thereby enhancing the peak strength (Betterman et al., 1995). To the author’s knowledge, the scant work is available in the literature regarding the fracture toughness of concrete reinforced with the hybridization of micro basalt fiber and coarse polypropylene fiber.

In this paper, coarse polypropylene fiber and basalt fiber were selected for single blending and mixed blending in concrete. The effect of the two fibers on the fracture toughness of concrete was studied by the three-point bending test, acoustic emission technology and double-K fracture theory of concrete. The theoretical cohesive toughness of polypropylene–basalt fiber-reinforced concrete (PBFRC) specimens was obtained by calculating three double-line softening constitutive curves and comparing with the measured cohesive toughness. Then, a double-line softening constitutive curve suitable for hybrid fibers was obtained.

2 Experimental Program

2.1 Materials

The corrugated coarse polypropylene fiber (CF) was provided by Ningbo Dacheng New Material Co., Ltd, and the basalt fiber (BF) was provided by Beijing Tongshen Composite Material Co., Ltd, whose shapes and properties are shown in Fig. 1 and Table 1.

Fig. 1
figure 1

External shapes of fibers: a CF; b BF.

Table 1 Properties of fibers.

The cement was PO 52.5 grade ordinary Portland cement. The coarse aggregates were stones with grain sizes of 5–10 mm and 10–20 mm, and the fine aggregates were sands whose dimensions are less than 5 mm. As shown in Fig. 2, the fine aggregate met the requirements of Chinese standard JGJ-52 (JGJ-52 2006). Carboxylic acid superplasticizer was used, whose water reduction rate was 15–30%.

Fig. 2
figure 2

Grading curve of machine-made sand.

2.2 Preparation of Specimens

Except for the difference in fiber type and quantity, the mixing ratio of other materials in each group of specimens remained the same to reduce the performance difference of concrete samples due to the difference in raw material performance. The concrete strength grade is C50, and the ratio of cementitious materials is m (cement): m (water): m (sand): m (stone): m (water reducing agent) = 456: 164: 787: 1010: 4.56.

A total of 13 different fiber content were designed, including one control group (no fiber), two groups of CF, two groups of BF, as well as eight groups of hybrid polypropylene–basalt fiber with different fiber content. The coarse polypropylene fiber content was selected as 6 kg/m3 and 9 kg/m3, while the basalt fiber content was 3 kg/m3 and 6 kg/m3 according to previous experimental research and engineering experience (Banthia, 2005; Deng et al., 2020b; Liang et al. 2019c; Zieliński & Olszewski, 2005). Parameters of each group specimen for the three-point bending test are shown in Table 2. The fiber concrete mixing procedures are listed in Fig. 3.

Table 2 Parameters of each group of specimens.
Fig. 3
figure 3

Mixing procedures of PBFRC.

The mixing, pouring, curing and determination of related parameters of the test piece are carried out in accordance with Chinese standard CECS 13 (CECS-13 2009) and GB/T 50080 (GB/T-50080 2016). Partial production procedures of specimens are shown in Fig. 4. The test specimen shape is shown in Fig. 5a: the size was L × t × h = 515 mm × 100 mm × 100 mm, the span length was S = 400 mm, and the relative notch depth was a0/h = 0.4. In addition, the curing age of all specimens when tested is 28 days. The acoustic emission instrument uses the SAEU2S-6 model acoustic emission collector and test system produced by Beijing Soft Island Times Technology Co., Ltd, which is mainly composed of sensors, amplifiers and acquisition boxes. Four acoustic emission probes were placed in the upper and lower center symmetrical positions of the left and right parts of the test piece, as shown in Fig. 5b.

Fig. 4
figure 4

Partial production procedures of specimens: a aggregate drying; b stir aggregates; c scatter basalt fiber; d scatter polypropylene fiber; e table vibrator; f coating maintenance; g cutting and polishing; and h specimen sample.

Fig. 5
figure 5

Schematic diagram of the test piece size and test arrangement: a dimensions of test specimen; b acoustic emission sensor layout.

2.3 Experimental Procedure

There were 13 groups of edge-notched simply supported concrete beams designed and fabricated with different fiber mixes for the three-point bending test according to Chinese standard DL/T5332 (DL/T5332-2005 2005). Three replicate specimens were conducted for each group.

The test apparatus is shown in Fig. 6. A CMT5504 microcomputer-controlled electronic universal testing machine was used for testing. The acoustic emission probes on the measured points were placed in advance and collected data while loading. The loading time and acoustic emission acquisition time were strictly controlled and synchronized to measure the cracking load and unstable load of the test specimen. The specimens were loaded with displacement control at a continuous rate of 0.1 mm/min. The displacement of the crack opening was measured by a clamping extensometer. The gauge length of the extensometer was 12.5 mm, the range was 5 mm, and the accuracy was 0.001 mm.

Fig. 6
figure 6

Test apparatus.

During loading, the cracks were carefully observed and recorded to prevent sudden damage to the extensometer break. The load–displacement (Pδ) curves were automatically generated by the testing machine system. In addition, the load–fracture opening-displacement (PCMOD) curves were measured by the clip-in extensometer. Then, the initiation cracking load and instability load of concrete in the three-point bending test were compared with acoustic emission data.

3 Results and Discussion

3.1 Workability

The concrete used in the test belongs to dry hard concrete, its poor flow properties mixing was measured slump not greater than 10 mm. Based on Chinese standard GB/T-5008 (GB/T-50080 2016), its rheological characteristics were evaluated by the test of Vebe consistometer, and the test result is shown in Fig. 7.

Fig. 7
figure 7

Fresh state properties of PBFRC.

Incorporating fiber makes the mixture of each group of PBFRC specimens become denser, which shows that the Vebe Consistency (VC) time becomes larger. Compared with the minimum content of coarse polypropylene fiber and basalt fiber which are 6 kg/m3 and 3 kg/m3, when the maximum content of polypropylene fiber and basalt fiber reaches 9 kg/m3 and 6 kg/m3, the VC time increased by 7.14% and 16.67%, respectively. Compared with A0, the VC time of A6–A8 with a total content of 6 kg/m3 increased by 8.70–13.04%, and A10–A12 with 9 kg/m3 increased by 21.74–26.09%. All show that increasing the amount of fiber will weaken the workability of the mixture. The cement paste in the matrix gradually adheres to the outer surface of the fibers, decreasing the free-flowing cement paste, and finally deteriorating the flow performance of the PBFRC mixture (Fei et al., 2018).

For specimens A5–A9 with a total content of 6 kg/m3, when the mixing ratio of CF and BF was 4:1 and 2:1, respectively, the VC time increased by 17.39% and 13.04%. In addition, when the mixing ratio of was 1:4 and 1:2, both the VC time of concrete mixture increased by 8.70%. This indicated that the smaller the aspect ratio of the fiber, the greater the hindrance to the fluidity of the mixture. The coarse polypropylene fiber has a greater effect on the rheological properties of the concrete mixture than basalt fiber. The reason may be that the distribution density of polypropylene fibers is larger and can form a network structure in the PBFRC mixture, hinder the sinking of aggregates and inhibit the flow of free slurry. Therefore, the fibers are more difficult to distribute in concrete matrix due to the larger friction force, which may result in poor flow properties (Smarzewski and D’Aniello 2018).

3.2 Load–Displacement Curves

The load–displacement (Pδ) curve and load–fracture opening-displacement (PCMOD) curve of 13 sets of concrete specimens were obtained from the three-point bending test of the notched beam, as shown in Fig. 8. See Appendix 1 for raw data.

Fig. 8
figure 8

Load–displacement curve and load-opening displacement curve.

In Fig. 8, concrete specimen A0 experienced obvious brittle failure, and its bearing capacity dropped after the peak load and completely disappeared with the rapid failure of the specimen. The peak load and residual load of the specimens increased to varying degrees. The rising sections of the Pδ curve and PCMOD curve of the 3-kg/m3 specimen A3 and 6-kg/m3 specimen A4 with single-basalt fiber are basically consistent with those of specimen A0. After reaching the peak load, there was also a cliff-like decline, the load decreased to approximately 10% of the peak load, an inflection point appeared, and the curve began to gently decline until it returned to zero. The Pδ curve and PCMOD curve of the 6-kg/m3 specimen A1 and 9-kg/m3 specimen A2 with single-polypropylene fiber are basically consistent with those of specimen A0 in the rising section and falling section of the cliff, and the inflection point was approximately 20% peak load. Then, the load showed a slight and gentle growth trend with the increase in displacement until the displacement was 2.5 mm. Specimen A2 had a larger peak load than A1, and A3 had a lower peak load than A4, so the specimens with polypropylene fiber have advantages compared to those with the same content of basalt fiber in the peak load. Thus, in the optimal content range, a higher content of the same type of fiber corresponds to better performance of the concrete. Meanwhile, the concrete with polypropylene fiber exhibited better toughness than that with basalt fiber.

The Pδ curves and PCMOD curves of the 6-kg/m3 specimens A5–A9 and 9-kg/m3 specimens A10–A12 were similar to those of the sample of single-mixed polypropylene fiber. The peak load and residual load of the specimen generally first increased and subsequently decreased with the increase in the basalt content, which indicates that the mass ratio significantly affects the toughening effect of the hybrid-fiber-reinforced concrete.

3.3 Initiation Cracking Load and Instability Load

Concrete is a brittle material, and the crack development under load is divided into three stages: initiation, stable expansion and instability (Xu, 1999). Acoustic emission technology can accurately determine the cracking point and instability point of concrete, which reflect the internal damage of concrete. Figure 9 matches the time–load curve and time-cumulative ring count curve of specimen A1.

Fig. 9
figure 9

Time–force-cumulative ring count curve of A1.

This method can effectively determine the initiation load and instability load of the concrete during the three-point bending test. The double-K fracture parameters of the specimens provide accurate data. The initiation cracking load (Pini), instability load (Pc) and critical crack opening displacement (CMODc) of each group of test specimens are shown in Table 3. See Appendix 2 for relevant complete data.

Table 3 The Pini, Pc and CMODc of each group specimen.

In Table 3, compared with plain concrete specimen A0, the addition of polypropylene fiber and basalt fiber increased the initiation cracking load Pini, instability load Pc and critical crack opening displacement CMODc. Compared with A0, specimen A1 of 6 kg/m3 and specimen A2 of 9 kg/m3 with single-polypropylene fiber had Pini increased by 24.5% and 27.1%, Pc increased by 22.8% and 25.9%, and CMODc increased by 19.4% and 24.7%. Pini, Pc and CMODc of specimen A3 with 3 kg/m3 of only basalt fiber increased by 9.3%, 12.5%, and 10.2%, respectively, and Pini, Pc and CMODc of specimen A4 with 6 kg/m3 increased by 16.6%, 15.6% and 11.8%, respectively. Thus, the incorporation of fiber improves the brittleness of concrete, and polypropylene fiber has a more significant effect than basalt fiber.

Compared with specimen A1, the Pini and Pc of specimen A2 improved by 2.1% and 2.5%. Compared with specimen A4, the Pini and Pc of specimen A3 increased by 6.7% and 2.8%. These two controls indicate that in the optimal content range, the polypropylene fiber content of 6–9 kg/m3 has little effect on the cracking load and fracture load of concrete, while the basalt fiber content of 3–6 kg/m3 significantly increases the cracking load of concrete.

Compared with A0, the Pini, Pc and CMODc of specimens A5–A9 with the total amount of 6 kg/m3 improved by 14.8–30.9%, 14.5–27.8% and 8.1–30.9%, respectively. Pini, Pc and CMODc of specimens A10–A12 with a total amount of 9 kg/m3 increased by 29.5–37.8%, 24.6–33.3% and 23.4–36.6%, respectively. Thus, the mixed-fiber-reinforced concretes with different contents and mass ratios presented different fracture performance indices, which indicates that the mixed-fiber specimen had better load-bearing performance than the single-fiber specimen under appropriate mixing conditions.

The load conditions of the hybrid-fiber-reinforced concrete specimens with different amounts and mass ratios are shown in Fig. 10. For specimens A5–A9 with a total content of 6 kg/m3, both initiation cracking load and fracture load first increased and subsequently decreased. The initiation load of 5504 N and instability load of 6905 N of specimen A6 are the maximum values of the same total content. For specimens A10–A12 with a total admixture of 9 kg/m3, both initiation load and instability load showed a decreasing trend. The initiation cracking load of 5795 N and instability load of 7202 N of specimen A10 are the maximum values of the same total content. Thus, the mixing effect of the 9-kg/m3 fiber concrete is stronger than that of 6 kg/m3. When the mixing ratio of CF and BF is 2:1, the initiation load and instability load of hybrid-fiber-reinforced concrete specimens most obviously improved.

Fig. 10
figure 10

Relationship between load and mixing ratio.

3.4 Effect of Fiber on Double-K Fracture Parameters

The double-K fracture theory and simplified formula were proposed by Xu (1999), which well explained the fracture mechanism of concrete. The double-K fracture model believes that the fracture process of concrete is essentially the process of concrete’s own crack propagation under load. The process can be divided into three stages: the elastic stage when the crack does not propagate, the inelastic stage when the crack propagates steadily, and the instability stage when the crack propagates rapidly. By introducing the initiation toughness \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\) and instability toughness \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) to distinguish these three stages, that is the strength factor \(K\) of the crack tip of the concrete is compared with \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\) and \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\). When \(K < K_{{{\text{Ic}}}}^{{{\text{ini}}}}\), the crack is in the elastic stage. When \(K_{{{\text{Ic}}}}^{{{\text{ini}}}} < K < K_{{{\text{Ic}}}}^{{{\text{un}}}}\), the crack is in the inelastic stage. When \(K > K_{{{\text{Ic}}}}^{{{\text{un}}}}\), crack is in the unstable stage. The toughness parameter has a relatively clear physical meaning and guiding significance for practical engineering and theoretical research.

The calculation steps of fracture parameters refer to other studies of this research team (Liang et al., 2019a, 2019c). In addition, the calculation results are shown in Fig. 11. See Appendix 3 for relevant complete data.

Fig. 11
figure 11

Double-K fracture parameters and fracture energy diagrams of each group of specimens.

In Fig. 11a, the fracture toughness parameters \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\), \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\), and \(K_{{{\text{Ic}}, T}}^{C}\) of all fiber-added specimens increased compared to those of plain concrete specimen A0. As shown in Fig. 11b, the fracture energy of the fiber-added specimen is higher than that of the plain concrete specimen A0. Thus, both basalt fiber and polypropylene fiber can improve the fracture toughness parameters of concrete.

3.4.1 Single Doped Fiber Specimen

Compared specimen A1 of 6 kg/m3 with specimen A2 of 9 kg/m3 with coarse polypropylene fiber and specimen A3 of 3 kg/m3 with specimen A4 of 6 kg/m3 with basalt fiber. Ach pair has relatively similar fracture toughness parameters, although the amount of the latter is increased by 3 kg/m3 compared to the former. Thus, after the fiber content reaches a certain amount, increasing the content cannot continue to significantly improve the fracture toughness of the concrete. Compared with plain concrete A0, fracture energy \(G_{{\text{f}}}\) of specimens A1 and A2 increased by 225.7% and 264.3%, which is a much higher increase than those of specimens A3 and A4 (increased by 58.9% and 89.9%), so polypropylene fiber has a greater effect on the fracture energy of concrete than basalt fiber.

Fiber blending can improve the fracture toughness parameters of concrete, which is mainly affected by its type and amount. Compared with plain concrete A0, initial fracture toughness \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\) of specimens A1 and A2 increased by 12.6% and 14.7%, while specimens A3 and A4 increased by 18.0% and 18.9%, which indicates that polypropylene fiber has a less obvious effect on the initial fracture toughness of concrete than basalt fiber. The reason is that the basalt fiber has a smaller diameter, which can reduce the initial defects of the concrete matrix and make the concrete matrix denser (Deng et al., 2020a). Basalt fiber in the concrete matrix can share the stress of part of the crack tip and delay the generation and development of micro cracks (Jiang et al., 2016). Polypropylene fiber has a larger diameter, which has limited effect on the stress concentration of the prefabricated crack tip of the concrete and little effect on the micro cracks (Liang et al., 2020). As a result, polypropylene fiber causes a relatively smaller increase in initial fracture toughness of concrete than basalt fiber.

Unstable toughness \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) of specimens A3 and A4 increased by only 15.2% and 16.1%, while those of specimens A1 and A2 significantly increased by 23.5% and 26.9%. Measured cohesive toughness \(K_{{{\text{Ic}}, T}}^{C}\) of concrete reflects the magnitude of the load capacity that the specimen can withstand from cracking to instability. Compared to specimen A0, \(K_{{{\text{Ic}}, T}}^{C}\) of specimens A3 and A4 increased by only 5.3% and 6.2%, while those of specimens A1 and A2 significantly increased by 49.0% and 56.1%. Thus, polypropylene fiber has a greater impact on the fracture properties of concrete than basalt fibers.

The aspect ratio of polypropylene fiber is relatively small, and the load capacity of a single fiber is high (Liang et al., 2020). It can withstand the stress and energy released when the load is close to the instability load and the micro-cracks partially extend, and it will not be momentarily broken. Beside, it can also bear part of the stress after the micro-cracks penetrate the matrix, increase the fracture process unit cohesion of the zone and delay the time when micro cracks develop into macro cracks (Liang et al., 2019a). The elastic modulus of basalt fiber is relatively large, but its long diameter is relatively large, the load capacity of a single fiber is limited, and the bridging effect is small (Arslan, 2016). It is easily directly broken when the crack penetrates. Therefore, the instability toughness, cohesive toughness and fracture energy of concrete with basalt fiber to concrete are less improved than that with polypropylene fiber.

3.4.2 Mixed Fiber Specimens

Comparing all hybrid-fiber specimens of A5–A9 with a total content of 6 kg/m3 and A10–A12 with 9 kg/m3, the initial fracture toughness \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\), unstable toughness \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) and measured cohesive toughness \(K_{{{\text{Ic}}, T}}^{C}\) showed the same trend with the change in mixing ratio of polypropylene fiber and basalt fiber. Specimens A6 and A10 with the mass ratio of CF to BF is 2:1 have the largest increase in the same content group. Compared with specimen A1, the \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\), \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) and fracture energy \(G_{{\text{f}}}\) of specimen A6 with the same total content increased by 7.0%, 9.8% and 25.6%, respectively. Specimen A12 increased by 11.8%, 9.3% and 18.1%, respectively, compared to specimen A2 with the same total content. Thus, the mixing of polypropylene fiber and basalt fiber can produce a positive effect to simultaneously improve the initial fracture toughness, unstable toughness and fracture energy of concrete. Specimens A9 and A12 with a mass ratio of 1:4 have the smallest increase in the same content group. Compared to the 6-kg/m3 specimen A1, \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) and \(G_{{\text{f}}}\) of specimen A9 with the same total content decreased by 7.2% and 34.1%. Compared to the 9-kg/m3 specimen A2, \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) and \(G_{{\text{f}}}\) of specimen A12 with the same total content decreased by 0.3% and 9.0%. This mean that the improper mixing ratio of polypropylene fiber and basalt fiber produced a negative effect and prevented the two fibers from functioning.

Different blending ratios have different effects on the increase in fracture energy of concrete. In specimens A5–A9 with a total admixture of 6 kg/m3, the increase in fracture energy of the mixed fiber concrete is arranged from high to low as 2:1 > 4:1 > 1:1 > 1:2 > 1:4 (CF:BF). In specimens A10–A12 with a total content of 9 kg/m3, the increase in fracture energy of mixed fiber concrete is arranged from high to low as 2:1 > 1:1 > 1:2 (CF:BF). Specimens A6 and A10 with mass ratio of CF to BF is 2:1 have the largest fracture energy in the same group. In addition, the increase in \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) of specimens A5–A9 with a total content of 6 kg/m3 was 11.8–32.2%, and the increase in \(G_{{\text{f}}}\) was 114.5–309.2%. Meanwhile, the increase in \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\) of specimens A10–A12 with a total content of 9 kg/m3 was 26.5–38.7%, and the increase in \(G_{{\text{f}}}\) was 231.5–330.2%. Thus, the total blending amount of 9 kg/m3 had a better effect than 6 kg/m3.

The polypropylene fiber in the hybrid-fiber-reinforced concrete can reduce the crack length, and the basalt fiber can suppress the generation of micro-cracks. These two fibers work together to reduce the probability of micro-crack interpenetrating (Deng et al., 2020a). The effect of polypropylene fiber on the fracture toughness of concrete is more significant. When the proportion of polypropylene fiber begins to decrease, the reduction of polypropylene fiber decreases, and the effect of fiber mixing is greater than that of a small amount of polypropylene fiber (Liang et al. 2019c). Therefore, when the mixing ratio of polypropylene fiber and basalt fiber is greater than 2:1, the instability toughness of the hybrid-fiber concrete increases with the increase in proportion of polypropylene fiber. When the mixing ratio of polypropylene fiber and basalt fiber is less than 2:1, the polypropylene fiber reduction is too large, and the fiber mixing effect is not sufficient to offset the impact of the coarse polypropylene fiber reduction on the fracture toughness of the concrete, so the unstable toughness of hybrid-fiber concrete will decrease with the decrease in proportion of polypropylene fiber content.

3.5 Parameter Fitting of the Bilinear Softening Constitutive Curve of Hybrid-Fiber Concrete

The softening constitutive curve of concrete can reveal the change law of the cohesive force of concrete in the fracture process area, including linear and nonlinear types. The current research shows that the bilinear physical meaning is clear, which is close to the actual fracture and softening of concrete, and it is convenient for practical engineering application (Xu, 1999). Therefore, in this paper, the bilinear softening constitutive curve is used to calculate the theoretical cohesive toughness of each group of specimens, and the curve form is shown in Fig. 12. Compared with the measured cohesive toughness, the bilinear softening constitutive curve is consistent with the hybrid-fiber concrete.

Fig. 12
figure 12

Bilinear softening traction–separation law.

In the bilinear softening constitutive curve, ordinate σ is the cohesive stress, abscissa w is the crack opening displacement in the fracture process area, and (ws, σs) is the turning point coordinate. The values of σs, ws and w0 are different, and the form of the curve is also different.

The classic bilinear softening constitutive curves are shown below:

  1. 1.

    Peterson bilinear softening constitutive curve (Peterson, 1981):

    $$\left\{ \begin{aligned} \sigma_{{\text{s}}} &= {{f_{t} } \mathord{\left/ {\vphantom {{f_{t} } 3}} \right. \kern-\nulldelimiterspace} 3} \hfill \\ w_{{\text{s}}} &= {{0.8G_{{\text{f}}} } \mathord{\left/ {\vphantom {{0.8G_{{\text{f}}} } {f_{{\text{t}}} }}} \right. \kern-\nulldelimiterspace} {f_{{\text{t}}} }} \hfill \\ w_{0} &= {{3.6G_{{\text{f}}} } \mathord{\left/ {\vphantom {{3.6G_{{\text{f}}} } {f_{{\text{t}}} }}} \right. \kern-\nulldelimiterspace} {f_{{\text{t}}} }} \hfill \\ \end{aligned} \right.,$$
    (1)

    where \(G_{{\text{f}}}\) is the measured concrete fracture energy; \(f_{{\text{t}}}\) is the cube splitting tensile strength.

  2. 2.

    CEB-FIP Model Code 1990 bilinear softening constitutive curve (CEB-FIP, 1990):

    $$\left\{ \begin{aligned} \sigma_{{\text{s}}} & = 0.15f_{{\text{t}}} \hfill \\ w_{{\text{s}}} & = {{2G_{{\text{f}}} } \mathord{\left/ {\vphantom {{2G_{{\text{f}}} } {f_{{\text{t}}} - 0.15w_{0} }}} \right. \kern-\nulldelimiterspace} {f_{{\text{t}}} - 0.15w_{0} }} \hfill \\ w_{0} & = {{\alpha_{{\text{f}}} G_{{\text{f}}} } \mathord{\left/ {\vphantom {{\alpha_{{\text{f}}} G_{{\text{f}}} } {f_{{\text{t}}} }}} \right. \kern-\nulldelimiterspace} {f_{{\text{t}}} }} \hfill \\ \end{aligned} \right.,$$
    (2)

    where \(\alpha_{{\text{f}}}\) is the parameter related to the maximum particle size \(d_{\max }\) of the aggregate.

  3. 3.

    Bilinear softening constitutive curve proposed by Reinhardt and Xu (1999):

    $$\left\{ \begin{aligned} \sigma_{{\text{s}}} &= \frac{{f_{{\text{t}}} }}{{\alpha_{{\text{f}}} }}\left( {{{2 - f_{{\text{t}}} w_{{\text{s}}} } \mathord{\left/ {\vphantom {{2 - f_{{\text{t}}} w_{{\text{s}}} } {G_{{\text{f}}} }}} \right. \kern-\nulldelimiterspace} {G_{{\text{f}}} }}} \right) \hfill \\ w_{{\text{s}}} & = {\text{CTOD}}_{{\text{C}}} \hfill \\ w_{0} & = {{\alpha_{{\text{f}}} G_{{\text{f}}} } \mathord{\left/ {\vphantom {{\alpha_{{\text{f}}} G_{{\text{f}}} } {f_{{\text{t}}} }}} \right. \kern-\nulldelimiterspace} {f_{{\text{t}}} }} \hfill \\ \alpha_{{\text{f}}} & = {{\lambda - d_{\max } } \mathord{\left/ {\vphantom {{\lambda - d_{\max } } 8}} \right. \kern-\nulldelimiterspace} 8} \hfill \\ \end{aligned} \right.,$$
    (3)

    where CTODc is the opening displacement of the virtual crack tip; \(\lambda\) is the correction parameter related to the deformation characteristics of concrete, whose value is 5–10.

The calculation of the bilinear softening constitutive curves of each theory is summarized, and the calculation results are shown in Table 4.

Table 4 Comparison of \(K_{{{\text{IC}},T}}^{C}\) and \(K_{{{\text{IC}},E}}^{C}\) (MPa m1/2).

In Table 4, the cumulative square sum ϒ rarely exceeds 0.2, which represents the difference between theoretical cohesive toughness \(K_{{{\text{Ic}}, E}}^{C}\) and measured cohesive toughness \(K_{{{\text{Ic}}, T}}^{C}\) calculated by different softening constitutive curves for each group of test specimens; hence, the double-line softening constitutive curve is highly consistent with the actual softening stress distribution. It is reasonable to use the double-line softening constitutive curve to describe the fracture toughness law of plastic steel–basalt fiber concrete. The calculated values of Peterson’s softening constitutive curve (Peterson, 1981) and softening constitutive curve recommended by the European standard CEB-FIP Model Code (CEB-FIP, 1990) are within the calculated value of the softening constitutive curve improved by Xu and Reinhardt. The reason is that the improved softening constituency of Reinhardt and Xu (1999) introduces correction parameter λ, which expands the value range of \(\sigma_{{\text{s}}}\), \(w_{{\text{s}}}\) and other parameters, and improves the adaptability to the stress distribution of different concrete specimens. Parameters of the bilinear softening curve of each fiber concrete specimen are shown in Table 5.

Table 5 Parameters of bilinear softening curve of hybrid-fiber concrete.

According to cumulative square sum ϒ, the theoretical cohesive toughness \(K_{{{\text{Ic}}, E}}^{C}\) obtained by the softening curves of Xu and Reinhardt is the closest to the measured cohesive toughness \(K_{{{\text{Ic}}, T}}^{C}\). For plain concrete, the best value for λ is 5. When the total admixture is 3-kg/m3 and 6-kg/m3 single-admixed basalt fiber concrete, the best value for λ is 6. When the total admixture is 6-kg/m3 and 9-kg/m3 single-mixed polypropylene-fiber-reinforced concrete, it is appropriate to choose λ as 5. Thus, the effect of the total admixture on the softening curve of single-fiber concrete is not obvious. For hybrid-fiber concrete, the total fiber content and mixing ratio have a greater impact on the softening curve of concrete. The best value of λ is both 5 and 6: the value is 5 when the polypropylene fiber quality is relatively high, while it is 6 when the basalt fiber mass is relatively high.

4 Conclusions

The effect of hybrid fibers on the fracture toughness of concrete has been fully investigated by the three-point bending test of notched beams and acoustic emission technology with the double-K fracture theory of concrete. Some major conclusions may be summarized as follows:

  1. 1.

    Increasing the amount of fiber will weaken the workability of the mixture, which the optimum content of coarse polypropylene is 6 kg/m3 and basalt fiber is 3 kg/m3. In addition, coarse polypropylene fiber has a greater effect on the rheological properties of the concrete mixture than basalt fiber.

  2. 2.

    Increasing the content of fiber will not continue to significantly increase the fracture toughness of the concrete. The fracture toughness parameters of specimen A1 of 6 kg/m3 and A2 of 9 kg/m3 with coarse polypropylene fiber, and the specimen A3 of 3 kg/m3 and A4 of 6 kg/m3 with basalt fiber are relatively close.

  3. 3.

    Incorporation of fibers improves the fracture toughness parameters of concrete, but different fibers have different lifting ranges for different fracture parameters. The polypropylene fiber has a larger increase in unstable toughness, and the increase in initial fracture toughness of basalt fiber is greater.

  4. 4.

    The optimal masse ratio of the polypropylene–basalt fiber is 2:1. When the mixing ratio is greater than or equal to 1:1, the fracture parameter of the hybrid-fiber specimens is higher than that of the single-fiber blend specimen. When the blending ratio is less than or equal to 1:2, the fracture parameter of the hybrid-fiber specimens is lower than that of the single-fiber blending specimen.

  5. 5.

    The softening curves proposed by Xu and Reinhardt are most consistent with the test results. The best value of correction parameter λ is 5 for plain concrete and single-polypropylene–fiber-reinforced concrete, while it is 6 for single-basalt fiber. For hybrid-fiber-reinforced concrete, λ is 5 and 6 when the polypropylene and basalt fiber masses are relatively high, respectively.

Availability of data and materials

The data and materials had been included in the manuscript.

References

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by the Natural Science Foundation of Chongqing, China (Grant No. cstc2018jscx-mszdX0071) and the Graduate Scientific Research and Innovation Foundation of Chongqing, China (Grant No. CYS18025, No. CYS20027). This support is gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Contributions

All authors contribute equally to this paper. Conceptualization: NL; writing—original draft: LR and ST; supervision: XL and ZZ; writing—review and editing: NL, ZD and RY. All authors have agreed to the published version of the manuscript. All authors read and approved the final manuscript.

Authors’ information

Ninghui Liang is an Associate Professor in the School of Civil Engineering at Chongqing University. Lianxi Ren is a Master Student in the School of Civil Engineering at Chongqing University. Shuo Tian is a Master Student in the School of Civil Engineering at Chongqing University. Xinrong Liu is a Full Professor in the School of Civil Engineering at Chongqing University. Zuliang Zhong is an Associate Professor in the School of Civil Engineering at Chongqing University. Zhiyun Deng Ph.D. Student in the School of Civil Engineering at Chongqing University. Ru Yan is a Master Student in the School of Civil Engineering at Chongqing University.

Corresponding author

Correspondence to Ninghui Liang.

Ethics declarations

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Journal information: ISSN 1976-0485 / eISSN 2234-1315

Appendices

Appendices

Appendix 1: Load–Displacement Curves

The load–displacement (Pδ) curve and load–fracture opening-displacement (PCMOD) curve of 13 sets of concrete specimens.

figure a
figure b
figure c
figure d
figure e
figure f
figure g
figure h
figure i
figure j
figure k
figure l
figure m

Note: One of the test specimens in the A12 group failed to obtain the test data due to errors in the test operation, so the A12 group only had two sets of data.

Appendix 2: Load–Displacement Parameters

Related load–displacement parameters of all specimens

Specimen

Initiation cracking load Pini (N)

Instability load Pc (N)

Critical fracture process zone width CTODc (mm)

Critical crack opening displacement CMODc (mm)

A0

A0–1

4360

5489

0.0089

0.0354

A0–2

4126

5308

0.0089

0.0351

A0–3

4180

5413

0.0088

0.035

Average

4204

5403

0.0089

0.0352

A1

A1–1

4984

6367

0.0124

0.0429

A1–2

5411

6850

0.0127

0.045

A1–3

5308

6692

0.0133

0.0454

Average

5234

6636

0.0128

0.0444

A2

A2–1

5635

7135

0.0139

0.0485

A2–2

5123

6518

0.0135

0.0445

A2–3

5276

6752

0.0134

0.0463

Average

5345

6802

0.0136

0.0464

A3

A3–1

4559

5974

0.0102

0.0373

A3–1

5102

6465

0.0108

0.041

A3–3

4464

5793

0.0117

0.0382

Average

4595

6077

0.0109

0.0388

A4

A4–1

4893

6254

0.0108

0.0451

A4–2

4991

6315

0.0115

0.0457

A4–3

4826

6166

0.0109

0.0453

Average

4903

6245

0.0110

0.0454

A5

A5–1

5606

7015

0.0135

0.0471

A5–2

5217

6602

0.0139

0.0459

A5–3

5162

6564

0.0133

0.0452

Average

5328

6727

0.0136

0.0461

A6

A6–1

5614

7069

0.0141

0.0493

A6–2

5352

6715

0.0147

0.0477

A6–3

5546

6932

0.0145

0.0491

Average

5504

6905

0.0144

0.0487

A7

A7–1

5377

6665

0.0137

0.0458

A7–2

5515

6794

0.0134

0.0464

A7–3

5377

6675

0.0131

0.0448

Average

5425

6711

0.0134

0.0457

A8

A8–1

5079

6436

0.0120

0.0433

A8–2

4881

6151

0.0114

0.0419

A8–3

5270

6637

0.0115

0.0427

Average

5076

6408

0.0117

0.0426

A9

A9–1

4778

6160

0.0101

0.0391

A9–2

4990

6362

0.0109

0.0412

A9–3

4715

6044

0.0112

0.0402

Average

4828

6189

0.0107

0.0402

A10

A10–1

5985

7408

0.0161

0.0525

A10–2

5723

7166

0.0159

0.0512

A10–3

5676

7031

0.0155

0.0502

Average

5795

7202

0.0159

0.0508

A11

A11–1

5585

6973

0.0154

0.0497

A11–2

5602

6987

0.0148

0.0488

A11–3

5386

6853

0.0150

0.0487

Average

5524

6936

0.0150

0.0491

A12

A12–1

5485

6784

0.0154

0.046

A12–2

5403

6679

0.0148

0.0458

Average

5444

6732

0.0151

0.0459

  1. One of the test specimens in the A12 group failed to obtain the test data due to errors in the test operation, so the A12 group only had two sets of data

Appendix 3: Fracture Toughness Parameters

The fracture toughness parameters \(K_{{{\text{Ic}}}}^{{{\text{ini}}}}\), \(K_{{{\text{Ic}}}}^{{{\text{un}}}}\), and \(K_{{{\text{Ic}}, T}}^{C}\) of all specimens

Specimen

\(a_{{\text{c}}}\)/mm

\(\Delta a\)/mm

\(K_{{{\text{Ic}}}}^{{{\text{ini}}}} /\left( {{\text{MPa}}\;{\text{m}}^{ - 0.5} } \right)\)

\(K_{{{\text{Ic}}}}^{{{\text{un}}}} /\left( {{\text{MPa}}\;{\text{m}}^{ - 0.5} } \right)\)

\(K_{{{\text{Ic}}}}^{{\text{c}}} /\left( {{\text{MPa}}\;{\text{m}}^{ - 0.5} } \right)\)

A0

A0–1

44.037

4.037

1.187

1.627

0.440

A0–2

44.147

4.147

1.169

1.609

0.440

A0–3

44.079

4.079

1.164

1.608

0.443

Average

44.088

4.088

1.174

1.615

0.441

A1

A1–1

46.411

6.411

1.280

1.919

0.639

A1–2

45.593

5.593

1.354

2.037

0.683

A1–3

46.555

6.555

1.332

2.026

0.694

Average

46.306

6.306

1.322

1.994

0.672

A2

A2–1

46.194

6.194

1.403

2.137

0.734

A2–2

46.692

6.692

1.299

1.982

0.682

A2–3

46.358

6.358

1.335

2.032

0.697

Average

46.415

6.415

1.346

2.050

0.704

A3

A3–1

44.774

4.774

1.336

1.825

0.489

A3–1

44.793

4.793

1.480

1.915

0.435

A3–3

46.152

6.152

1.338

1.811

0.473

Average

45.240

5.240

1.385

1.850

0.465

A4

A4–1

45.013

5.013

1.391

1.867

0.475

A4–2

45.421

5.421

1.423

1.907

0.484

A4–3

45.180

5.180

1.374

1.850

0.476

Average

45.205

5.205

1.396

1.875

0.478

A5

A5–1

46.296

6.296

1.398

2.108

0.710

A5–2

47.028

7.028

1.336

2.028

0.692

A5–3

46.726

6.726

1.313

1.998

0.685

Average

46.683

6.683

1.349

2.044

0.695

A6

A6–1

46.932

6.932

1.437

2.164

0.727

A6–2

47.505

7.505

1.379

2.093

0.714

A6–3

47.297

7.297

1.428

2.147

0.718

Average

47.245

7.245

1.415

2.135

0.720

A7

A7–1

46.851

6.851

1.399

2.036

0.637

A7–2

46.493

6.493

1.428

2.053

0.625

A7–3

46.412

6.412

1.382

2.012

0.631

Average

46.585

6.585

1.403

2.034

0.631

A8

A8–1

45.870

5.870

1.407

1.909

0.502

A8–2

45.826

5.826

1.351

1.822

0.471

A8–3

45.292

5.292

1.444

1.935

0.491

Average

45.663

5.663

1.401

1.889

0.488

A9

A9–1

44.905

4.905

1.330

1.776

0.446

A9–2

45.192

5.192

1.395

1.850

0.455

A9–3

45.786

5.786

1.334

1.788

0.454

Average

45.294

5.294

1.353

1.805

0.452

A10

A10–1

47.345

7.345

1.552

2.297

0.745

A10–2

47.496

7.496

1.487

2.233

0.745

A10–3

47.483

7.483

1.477

2.190

0.713

Average

47.442

7.442

1.505

2.240

0.734

A11

A11–1

47.451

7.451

1.495

2.169

0.674

A11–2

47.073

7.073

1.489

2.149

0.660

A11–3

47.396

7.396

1.437

2.129

0.691

Average

47.307

7.307

1.474

2.149

0.675

A12

A12–1

46.520

6.520

1.495

2.052

0.557

A12–2

46.730

6.730

1.481

2.033

0.552

Average

46.625

6.625

1.488

2.043

0.554

  1. One of the test specimens in the A12 group failed to obtain the test data due to errors in the test operation, so the A12 group only had two sets of data

The fracture energy of all specimens

Specimen

W1 (N m)

W2 (N m)

Gf (N/m)

Increase (%)

A0

A0–1

0.829

0.029

143.1

0

A0–2

0.731

0.030

127.0

A0–3

0.906

0.031

156.1

Average

0.822

0.030

142.1

A1

A1–1

2.668

0.181

474.9

225.7

A1–2

2.555

0.150

450.7

A1–3

2.580

0.197

462.8

Average

2.601

0.176

462.8

A2

A2–1

3.079

0.156

539.1

264.3

A2–2

2.822

0.160

497.0

A2–3

2.941

0.159

516.7

Average

2.947

0.158

517.6

A3

A3–1

1.379

0.099

246.3

58.9

A3–1

1.227

0.073

216.7

A3–3

1.210

0.075

214.2

Average

1.272

0.082

225.7

A4

A4–1

1.35

0.079

238.3

89.9

A4–2

1.655

0.068

287.2

A4–3

1.602

0.102

284.0

Average

1.536

0.083

269.8

A5

A5–1

3.430

0.153

597.1

292.1

A5–2

3.277

0.164

573.5

A5–3

2.874

0.156

501.0

Average

3.194

0.158

557.2

A6

A6–1

3.43

0.747

597.1

309.2

A6–2

3.277

0.778

573.5

A6–3

3.288

0.738

574.0

Average

3.332

0.754

581.5

A7

A7–1

2.821

0.155

496.1

247.1

A7–2

2.770

0.159

488.3

A7–3

2.822

0.149

495.2

Average

2.804

0.154

493.2

A8

A8–1

2.062

0.144

367.7

164.8

A8–2

2.145

0.149

382.4

A8–3

2.132

0.141

378.9

Average

2.113

0.145

376.3

A9

A9–1

1.151

0.138

314.7

114.5

A9–2

1.536

0.140

279.3

A9–3

1.781

0.140

320.2

Average

0.149

0.139

304.8

A10

A10–1

3.702

0.173

645.9

330.2

A10–2

3.229

0.152

593.6

A10–3

3.402

0.165

594.5

Average

3.444

0.163

611.3

A11

A11–1

2.907

0.142

578.3

302.7

A11–2

3.049

0.147

562.7

A11–3

2.881

0.153

575.6

Average

2.946

0.147

572.2

A12

A12–1

2.819

0.145

494.1

231.4

A12–2

2.540

0.147

447.8

Average

2.680

0.146

471.0

  1. One of the test specimens in the A12 group failed to obtain the test data due to errors in the test operation, so the A12 group only had two sets of data

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liang, N., Ren, L., Tian, S. et al. Study on the Fracture Toughness of Polypropylene–Basalt Fiber-Reinforced Concrete. Int J Concr Struct Mater 15, 35 (2021). https://doi.org/10.1186/s40069-021-00472-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40069-021-00472-x

Keywords